Instructions / Assembly

12
English
© 2015 Schneider Electric. All rights reserved.
Wiser Air Installation Guide V13
www.wiserhome.com
Wiser Air Installation Guide V13
www.wiserhome.com
13
English
Interactive display
When a user interacts with Wiser Air’s touchscreen, the display will change to show
the following information.
For more information on Wiser Air’s functionality, please consult the online user guide
at: https://www.wiserhome.com/support
Figure 6. Interactive display.
Brings up the display of the
Home, Sleep and Away
Ready Modes
Brings up the Override
Schedule, which lists the
timing of Ready Mode
changes performed by
Wiser Air
Displays the menu
options available
Inside
temperature
controls
Current weather
and outside
temperature
Appendix
Wiser Wire Extender Kit
Introduction
The Wiser Wire Extender Kit is intended for use when a common wire (C) from the
HVAC control board is not available. If you are unsure whether you have the HVAC
wire present, refer to the picture taken in Step 3 of the Installation procedure for Wiser
Air. The picture can also help you determine whether you have a 4 or 5-wire system
in place.
The wire extender kit contains a diode pair and a Printed Control Board (PCB)
assembly. To open the board pinch and pull (Fig. 7).
Figure 7. Wire Extender Kit.
W
Y
HAZARD OF ELECTRICAL SHOCK
The following installation procedure should be performed by qualied personnel:
Knowledgeable about and licensed in accordance with local electrical
installation code requirements.
Able to read, interpret, and follow the instructions and precautions provided.
Trained on the operation and fundamentals of residential HVAC apparatus, and
familiar with the associated hazards.
Failure to follow these instructions can result in personal injury and/or
damage to Wiser Air.
WARNING