13
SunEzy VDE, RD, DK (outdoor)
Models VDE-RD SunEzy 400E SunEzy 600E SunEzy 6065
Models DK SunEzy 4065 SunEzy 4665 SunEzy 6065
Electrical specifications
Input (DC)
RecommendedPVpower 3.2to4.4kW 4.0to5.0kW 4.8to6.3kW
MPPT,voltagerange(fullpower) 250to450V 200to700V 230to500V
MPPT,voltagerange 150to450V 150to700V 180to550V
MPPT,numberoftrackers 1 3 1
Max.opencircuitvoltage 500V 750V 550V
Max.DCcurrent 20A 3×8.5A 27.5A
Inherentoperatingconsumption 7W 9W 8W
Nighttimetareloss <0.4W <0.5W <0.5W
Output (AC)
Max.continuousoutputpower 4.4kW 5.0kW 6.0kW
NominalACpower 4.0kW 4.6kW 6.0kW
NominalACvoltage 230V, single-phase 230V, single-phase 230V, single-phase
Nominalfrequency 50Hz 50Hz 50Hz
Max.ACcurrent 20A 25A 28.6A
Powerfactor >0.99 >0.99 >0.99
Efficiency
Maximum >96% >96% >97%
European >95% >94.5% >96%
General specifications
Enclosurerating IP65 IP65 IP65
Enclosure Metallic Metallic Metallic
Weight 19.5kg(42.99lb) 27kg(59.52lb) 30.6kg(67.46lb)
Dimensions(HxWxD) 38.6×43.4×13.5cm 53×43×13cm 53.1×43×15.5cm
(15.2x17.09x5.31in) (20.87x16.93x5.12in) (20.91x16.93x6.1in)
Operatingtemperaturerange -20°Cto55°C(-4°Fto131°F) -20°Cto55°C(-4°Fto131°F) -20°Cto55°C(-4°Fto131°F)
Relativehumidity 0to95% 0to95% 0to95%
PartnumbermodelsVDE-RD PVSNV1400E PVSNV1600E PVSNV16065
PartnumbermodelsDK PVSNV14065 PVSNV14665 PVSNV16065
Features and options
Coolingmethod Naturalconvection-nofans Naturalconvection-nofans Naturalconvection-nofans
Display LCD1line16digits LCD2lines16digits LCD1line16digits
DCconnection 3pairsofMC4connector 1pairofMC4connector/MPPT 2pairsofMC4connector/MPPT
Externalcommunicationport RS232standard(RS485option) RS232standard(RS485option) RS232standard(RS485option)
Communicationprotocol Proprietary Proprietary Proprietary
Country dependant features
For models SunEzy 400E-600E-6065
Decouplingprotectionchoice byselectionatinitialisation byselectionatinitialisation byselectionatinitialisation
Decouplingprotectionacc.VDE0126-1-1 Yes Yes Yes
Decouplingprotectionacc.RD1663(Spain) Yes Yes Yes
DCreversepolarityprotection Yes Yes Ye s
DCResidualcurrentmonitoringunit acc.VDE0126-1-1 acc.VDE0126-1-1 acc.VDE0126-1-1
For models SunEzy 4065-4665-6065
DecouplingprotectionaccordingDK5940 Yes Yes Ye s
DCreversepolarityprotection Yes Yes Ye s
Regulatory approvals
EULVDirective Inacc.withEN50178 Inacc.withEN50178 Inacc.withEN50178
EUEMCDirective Inacc.withEN61000-3-X/-6-X Inacc.withEN61000-3-X/-6-X Inacc.withEN61000-3-X/-6-X
EURoHSDirective Compliant Compliant Compliant
VDE0126-1-1 ApprovedbyVDE ApprovedbyVDE ApprovedbyVDE
DK5940 ApprovedbyDK ApprovedbyDK ApprovedbyDK
Markings CE,VDE,VDE-GS,DK CE,VDE,VDE-GS,DK CE,VDE,VDE-GS,DK
Specificationsaresubjecttochangewithoutnotice.