Technical Data Bulletin

19-140
© 2019 Schneider Electric
All Rights Reserved
Foot Switches
9002A Heavy Duty Industrial
schneider-electric.us
Class 9002
Approximate Dimensions
3.50
89
5.81
148
8.56
216
4.50
114
.38
10
.94
24
2.94
75
(3) .34 Dia. Mtg. Holes
9
3/4 14 Pipe Tap
Types AW1, AW5, AW11, AW13 and AW21
3/4-14 NPT
3.50
89
1.44
37
6.87
174
.94
24
9.00
229
5.38
137
4.84
123
(5) .34 Dia. Mtg. Holes
9
Types AW2, AW6, AW12, AW14 and AW22
Dual Dimensions:
INCHES
Millimeters
3.50
89
5.63
143
5.81
147
5.02
128
.94
24
2.87
73
1.25
32
6.40
163
2.90
74
1.84
47
8.56
217
6.62 Typ.
168
11.13
283
(5) .34 Dia. Mtg. Holes
9
3/4 14 Pipe Tap
4.60
117
5.73
146
6.26
159
Types AW117, AW119, AW123, AW124
Types AW132, AW133 and AW134 (without safety door)
Table 19.405: Maximum Current Ratings For Control Circuit Contacts
Type
Volts
AC Amperes
Volts
DC Amperes
Inductive
35% Power
Factor
Resistive
75% Power
Factor
Inductive
and Resistive
Make Break
Make,
Break
and
Continuous
Make and Break
Continuous
Single
Throw
Double
Throw
AW1 through AW10,
AW117, AW119,
AW132
120
240
480
600
40
20
10
8
15
10
6
5
15
10
6
5
125
250
600
2.0
0.5
0.1
0.5
0.2
0.02
15
15
15
AW13, AW14, AW15,
AW133
120
240
480
600
30
15
7.5
6
3
1.5
0.75
0.6
3
1.5
0.75
0.6
125
250
600
1.0
0.3
0.1
0.2
0.1
10
10
10
AW11, AW12
115
230
36
18
6
3
125
250
2.2
1.1
AW21, AW22,
AW123
120
240
480
600
15.0
7.5
3.75
3.0
1.5
0.75
0.375
0.3
10
10
10
10
AW124
120
240
480
600
60
30
15
12
6
3
1.5
1.2
10
10
10
10
120
240
600
1.1
0.55
0.2
10
10
10
NOTE: Double throw switches are rated 250 Vdc maximum.
Table 19.406: Contact Symbol—Two Stage
Snap Switch
Pedal
Unit Circuit
Up
Half Down Full Down
1
A1 0 1 1
B1 1 0 0
2
A2 1 1 0
B2 0 0 1
NOTE: 0 = Open 1 = Closed
Table 19.407: Contact Symbol—Four Stage
Snap Switch
Pedal Position
Unit Circuit
Up
Down
1
1A1 0 0 1 1 1
1B1 1 1 0 0 0
2A1 0 1 1 1 1
2B1 1 0 0 0 0
2
1A2 1 1 1 0 0
1B2 0 0 0 1 1
2A2 1 1 1 1 0
2B2 0 0 0 0 1
19
PUSH BUTTONS AND OPERATOR
INTERFACE