Push Buttons and Pilot Lights
Selection Guide
Refer to Catalogs DIA5ED2121212EN*, DIA5ED2121213EN**, DIA5ED2120503EN***, and 9001CT1103****
Push Button Selection Guide
Family
XB4 XB5 XB7 9001K 9001SK 9001KX
Type of Product
*22 mm Push Button
(metal)
**22 mm Push Button
(plastic)
***22mm Push Button
(plastic)
****30 mm Push Button
(metal)
****30 mm Push Button
(plastic)
****30 mm Push Button
(metal, square)
Mounting Hole
Diameter
22.5 mm 22.5 mm 22.5 mm
31 mm
(1.22 in)
31 mm
(1.22 in)
31 mm
(1.22 in)
Approvals
UL Listed File E164353,
CCN NKCR
UL Recognized File
E164353. CCN NKCR2
UL Listed File E164353,
CCN NKCR
UL Recognized File
E164353., CCN NKCR2
UL File E164353, CCN
NKCR
UL File E78403. CCN
NKCR
UL File E78403. CCN
NKCR
UL File E78403. CCN
NKCR
CSA File LR44087.
Class 3211-03
CSA File LR44087.
Class 3211-03
CSA File LR44087-122
Class 3211-03
CSA File LR25490.
Class 3211-03
CSA File LR25490.
Class 3211-03
CSA File LR25490.
Class 3211-03
Conforming to
Standards
CE Marked
RoHS Compliant
CE Marked
RoHS Compliant
CE Marked
RoHS Compliant
CE Marked
RoHS Compliant
CE Marked
RoHS Compliant
CE Marked
RoHS Compliant
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-5-5
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-5-5
EN/IEC 60947-1,
EN/IEC 60947-5-1 for
push buttons, pilot
lights, illuminated push
buttons and selector
switches
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-5,
EN/IEC 60947-1 EN/IEC 60947-1 EN/IEC 60947-1
EN/IEC 60204-1 and
EN/ISO 13850: 2006
(trigger action and
mechanical latching
emergency stop push
buttons)
EN/IEC 60204-1 and
EN/ISO 13850: 2006
(trigger action and
mechanical latching
emergency stop push
button).
EN/IEC 60204-1 and
EN/ISO 13850 for
Emergency Stop trigger
action push buttons
EN/IEC60947-5-1 EN/IEC60947-5-1 EN/IEC60947-5-1
EN/IEC 60364-5-53
(emergency switching of
mechanical latching push
buttons)
EN/IEC 60364-5-53
(emergency switching of
mechanical latching push
buttons)
EN/IEC60947-5-4 EN/IEC60947-5-4 EN/IEC60947-5-4
—
EN81-1 (emergency stop
trigger action and
mechanical latching push
buttons with mechanical
state indicator)
JIS C 4520 JIS C 4520 JIS C 4520 and 852 JIS C 4520 and 852 JIS C 4520 and 852
UL 508 UL 508 UL 508 UL 508 UL 508 UL 508
CSA C22.2 No.14 CSA C22.-2 No.14 CSA C22 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14
GOST GOST
CCC CCC CCC
GB 14048.5 for all XB7
range
Degree of
Protection
IP65, IP69, IP69K IP65, IP69, IP69K IP54, IP65
IP65 IP65 IP66
IP66 for booted IP66 for booted — — — —
NEMA 1, 2, 3, 4, 4X, 12, 13
NEMA 1, 2, 3, 3R, 4, 4X, 12,
13
NEMA 3, 4, 12 NEMA 1, 2, 3, 3R, 4, 12, 13
NEMA 1, 2, 3, 3R, 4, 4X,
12, 13
NEMA 1, 2, 3, 3R, 4, 12,
13
Operating
Temperature F°
(C°)
-40 to 158 (-40 to 70) -40 to 158 (-40 to 70) -13 to 158 (-25 to 70) -22 to 140 (-30 to 60) -22 to 140 (-30 to 60) -22 to 140 (-30 to 60)
Storage
Temperature F°
(C°)
-40 to 158 (-40 to 70) -40 to 158 (-40 to 70) -40 to 158 (-40 to 70) -40 to 158 (-40 to 70) -40 to 158 (-40 to 70) -40 to 158 (-40 to 70)
Electric Shock
Protection
Class I Class I — Class II Class II Class II
Electrical
Consumption
LED
24 Vac/Vdc: 18 mA 24 Vac/Vdc: 18 mA Illuminated Push
Buttons:
24V - 18mA
120V - 12mA
230V - 22mA
Pilot Lights
24V - 20mA
120V - 18mA
230V - 16mA
Incandescent and LED
bulbs.
For ratings, see
Standard Light Modules,
page 19-91.
Incandescent and LED
bulbs.
For ratings, see
Standard Light Modules,
page 19-91.
Incandescent
120 Vac: 14 mA 120 Vac: 14 mA
240 Vac: 14 mA 240 Vac: 14 mA
Rated
Operational
Characteristics
AC-15; B600
Ue = 600 Vac and le = 1.2 A
Ue = 240 Vac and
le = 3A
Ue = 120 Vac and le = 6A
Continuous 10 A
AC-15; B600
Ue = 600 Vac and le = 1.2 A
Ue = 240 Vac and le = 3 A
Ue = 120 Vac and le = 6 A
Continuous 10 A
AC-14; D300
Ue = 240 Vac and le =
0.3A
Ue = 120 Vac and le =
0.6A
Continuous 4 A
AC-15; A600
Continuous 10 A
AC-15; A600
Continuous 10 A
AC-15; A600
Continuous 10 A
DC-13; Q600
Ue = 600 Vdc and
le = 0.1 A
Ue = 250 Vdc and
le = 0.27 A
Ue = 125 Vdc and
le = 0.55 A
DC-13; Q600
Ue = 600 Vdc and
le = 0.1 A
Ue = 250Vdc and
le = 0.27 A
Ue = 125 Vdc and
le = 0.55 A
DC-13; R300
Ue = 250 Vdc and le =
0.1A
Ue = 125 Vdc and le =
0.22A
DC-13; Q600
Ue = 600 Vdc and
le = 0.1 A
Ue = 250 Vdc and
le = 0.27 A
Ue = 125 Vdc and
le = 0.55 A
DC-13; Q600
Ue = 600 Vdc and
le = 0.1 A
Ue = 250 Vdc and
le = 0.27 A
Ue = 125 Vdc and
le = 0.55 A
DC-13; Q600
Ue = 600 Vdc and
le = 0.1 A
Ue = 250 Vdc and
le = 0.27 A
Ue = 125 Vdc and
le = 0.55 A
Connection
Type
IP20 Fingersafe Screw or Spring Terminal
Screw and captive
clamp terminal
connections Faston clip
connections (pilot lights)
IP20 Fingersafe Screw Terminal
Screw Terminal:
Spring Terminal:
Cable Size
1 x 24 AWG (0.22 mm²) min.
2 x 14 AWG (2.5 mm²) max.
2 x 16 AWG (1.5 mm²) max.
1 x 24 AWG (0.22 mm²) min.
2 x 14 AWG (2.5 mm²) max.
2 x 16 AWG (1.5 mm²) max.
1 x 24 AWG (0.22 mm²)
min.
2 x 16 AWG (1.5 mm²) max
1 x 24 AWG (0.22 mm²)
min.
2 x 16 AWG (1.5 mm²)
max
1 x 24 AWG (0.2 2mm²)
min.
2 x 16 AWG (1.5 mm²)
max
Digest Location XB4, page 19-24 XB5, page 19-43 XB7, page 19-68 Type K, page 19-72 Type SK, page 19-82 KX, page 19-102