Technical Data Bulletin
19-4
© 2019 Schneider Electric
All Rights Reserved
Selection Guide Control Stations
schneider-electric.us
Refer to Catalogs 9001CT1104 and 9001BR1301
Control Station Selection Guide
Family
XAL XAP 9001B 9001KY/SKY
Point of Purchase (PoP)
XALD02
XAPA1100
XAPA1104
NEMA 1
Surface Mounting
9001BG
••
NEMA 1
Flush Mounting
9001BF
••
NEMA 4
9001BW
••
NEMA 7 and 9
9001BR
••
9001KYSS3
9001KY3
9001KYAF3 9001SKY2
Type of Product/
Material
XALD—Polycarbonate
XALK—Polycarbonate
XAPA—glass filled polyester
XAPG—die cast zinc
XAPE—anodized aluminum
9001BG—plastic cover
9001BF—stainless steel
9001BW—die cast zinc
9001BR—cast aluminum
9001KYAF—sheet steel
9001KYSS—stainless steel
9001KY—die cast zinc
9001KZ—die cast zinc
9001SKY—Polyester
Push Buttons, Pendants,
Tower lights, Relays
Number of holes 1 to 3 0 to 16 1 to 3 1 to 6
Type of Operators XB5 (22mm) XB5 (22mm)
Built in
9001K/SK (30mm)
Available without
Operators
Yes Yes No Yes
Available with
Operators
Yes No Yes Yes
Approvals
UL File E164353
CCN NKCR
UL File E164353
CCN NKCR
UL File E78403
CCN NKCR
UL File E78403
CCN NKCR
UL, CSA, CE, ROHS
CSA File LR 44087
Class 3211-03
CSA File LR 44087
Class 3211-03
CSA File LR 25490
Class 3211-03
CSA File LR 25490
Class 3211-03
Conforming to
Standards
CE Marked CE Marked CE Marked CE Marked
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
EN/IEC 60947-1,
EN/IEC 60947-5-1,
EN/IEC 60947-5-4,
JIS C 4520 JIS C 4520 JIS C 4520 JIS C 4520
UL 508 UL 508 UL 508 UL 508
CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 CSA C22.2 No.14
Degree of Protection
1, 4, 4X, 13
IP65
IP66 - Booted
XAPA - 4, 4X, 12, IP65
XAPG - 4, 12, IP65
XAPE - 4, 4X, 12, IP65
9001BG - 1
9001BF - 1
9001BW - 4
9001BR - 7, 9
9001KYAF - 3, 13
9001KYSS - 3, 4, 4X, 13
9001KY - 3, 4, 13
9001KZ - 3, 13
9001SKY - 3, 4, 4X, 13
Operating Temperature
F° (C°)
-13 to 158 (-25 to 70) -13 to 158 (-25 to 70)
Storage Temperature F°
(C°)
-40 to 158 (-10 to 70) -40 to 158 (-10 to 70)
Cable Entry
No. 13 knock out
XAPA—undrilled
XAPG—Tapped 3/4NPT
XAPE—flush mount (n/a)
9001BG—1/2 &3/4 knockout
9001BF—N/A
9001BW—1/2-14NPT
9001BR—1/2-14NPT
9001KYAF—customer
provided
9001KYSS—G conduit hub
9001KY—customer provided
9001KZ—1/2 & 3/4 knockout
9001SKY—G conduit hub
Digest Location XAL, page 19-107 XAP, page 19-107 9001B, page 19-110 KY/SKY, page 19-112 PoP Products , page 19-114
19
PUSH BUTTONS AND OPERATOR
INTERFACE