Datasheet

91
Characteristics (continued)
Characteristics of illuminated units (pilot lights)
Mechanical characteristics
Vibration resistance Conforming to IEC 60068-2-6 Frequency: 12 to 500 Hz: 5 gn
Electric shock resistance Conforming to IEC 60068-2-27
Half sine wave acceleration 11 ms: 50 gn
Half sine wave acceleration 18 ms: 30 gn
Electrical characteristics
Cabling capacity Conforming to EN/IEC 60947-1 mm
2
Screw clamp and spring terminals
Min: 1 x 0.2 without cable end
(1 x 0.34 for linking)
Max: 2 x 1.5 with cable end
Rated insulation voltage Conforming to EN/IEC 60947-1 V Direct supply pilot light blocks (BA 9s bulb):
Ui = 250 degree of pollution 3
Pilot light blocks with integral LED:
Ui = 250 degree of pollution 3
Pilot light blocks with transformer:
Ui = 600 degree of pollution 3
Rated impulse withstand voltage Conforming to EN/IEC 60947-1 kV Direct supply pilot light blocks (BA 9s bulb):
Uimp = 4
Pilot light blocks with integral LED: Uimp = 4
Pilot light blocks with transformer: Uimp = 6
Specic characteristics of single light blocks with integral LED
Voltage limits For rated voltage V 12 V: 10 to 15 c; 10.2 to 13.8 a
24 V: 19.2 to15 c; 21.6 to 13.8 a
24 to 120 V: 19.2 to 132 c; 21.6 to 132 a
48 to 120 V: 40 to 132 a
230/240 V: 195 to 264 a
Current consumption Applicable to all colours mA Blocks with z 12 V supply: 18
Blocks with z 24 V supply: 18
Blocks with a 120 V supply: 14
Blocks with a 240 V supply: 14
Service life At rated voltage and at an
ambient temperature of 25 °C
H 100 000
Surge withstand Conforming to IEC 61000-4-5 kV 1
Resistance to fast transients Conforming to IEC 61000-4-4 kV 2
Resistance to electromagnetic elds Conforming to IEC 61000-4-3 V/m 10
Resistance to electrostatic discharges Conforming to IEC 61000-4-2 kV 8: in free air, in insulating parts
6: on contact, on metal parts
Direct parallel connection across inductive load
e.g.: contactor coil or solenoid
Maximum power of load VA
For high power applications ( 30 VA), a ZBZ Vp
LED suppressor must be connected across the
light block terminals (see page 121)
Electromagnetic emission Conforming to IEC 55011 Class B
Specic characteristics
Fixing nut
Head tightening torque N.m 2.2 (± 0.2)
Hour counters and annunciators
Voltage limits Hour counter and annunciator V ± 10% of the nominal voltage
Current consumption Hour counter mA XB5 DSB: 7 to 15
XB5 DSG: 8
XB5 DSM: 8
Annunciator mA 5
General:
page 80
References:
page 94
Dimensions:
page 146
General:
page 80
References:
page 94
Dimensions:
page 146
General:
page 80
References:
page 94
Dimensions:
page 146
General:
page 80
References:
page 94
Dimensions:
page 146
Control and signalling units Ø 22
Harmony
®
XB5 plastic
Pushbuttons, switches and pilot lights
1
2
3
4
5
6
7
8
9
10