Datasheet

Product data sheet
Characteristics
XPSAC5121
module XPSAC - Emergency stop - 24 V AC
DC
Main
Range of product Preventa Safety automation
Product or component-
type
Preventa safety module
Safety module name XPSAC
Safety module applica-
tion
For emergency stop and switch monitoring
Function of module Emergency stop
Switch monitoring
Safety level Can reach PL e/category 4 conforming-
to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 210.4 years conforming-
to EN/ISO 13849-1
PFHd = 3.56E-9 1/h conforming to EN/IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, clamping capac-
ity: 1 x 0.25...1 x 2.5 mm² flexible cable with ca-
ble end, without bezel
Captive screw clamp terminals, clamping capac-
ity: 1 x 0.25...1 x 1.5 mm² flexible cable with ca-
ble end, with bezel
Captive screw clamp terminals, clamping capac-
ity: 2 x 0.25...2 x 1 mm² flexible cable with ca-
ble end, without bezel
Captive screw clamp terminals, clamping capac-
ity: 2 x 0.5...2 x 1.5 mm² flexible cable with ca-
ble end, with double bezel
Captive screw clamp terminals, clamping capaci-
ty: 1 x 0.14...1 x 2.5 mm² flexible cable without ca-
ble end
Captive screw clamp terminals, clamping capac-
ity: 1 x 0.14...1 x 2.5 mm² solid cable without ca-
ble end
Captive screw clamp terminals, clamping capaci-
ty: 2 x 0.14...2 x 0.75 mm² flexible cable without ca-
ble end
Captive screw clamp terminals, clamping capac-
ity: 2 x 0.14...2 x 0.75 mm² solid cable without ca-
ble end
Output type Relay instantaneous opening 3 NO, volt-free
Number of additional-
circuits
1 solid state output
[Us] rated supply volt-
age
24 V AC (- 20...10 %)
24 V DC (- 20...20 %)
Complementary
Supply frequency 50/60 Hz
Power consumption in W <= 1.2 W DC
Power consumption in VA <= 2.5 VA AC
[Uc] control circuit voltage 24 V
Breaking capacity C300 : 180 VA, AC-15 (holding) for relay output
C300 : 1800 VA, AC-15 (inrush) for relay output
Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current 6 A per relay for relay output
[Ith] conventional free air thermal current 10.5 A
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Jun 18, 2018
1

Summary of content (2 pages)