Manual

MIT detection Tome 1 / chap. 3 / page 3 07/99
W913069670111 A13 1/2
Installation precautions
Précautions de mise en œuvre
Vorsicht bei der Inbetriebnhame
Precautión de instalatión
Consigli di messa in opera
Precaução de instalação
+++++++++++++++++--tm
XS1-M / XS2-M
Inductive proximity sensors XS1-M XS2-M
Détecteurs de proximité inductifs
Induktive Näherungsschalter
Detectores de proximidad inductivos
Interruttori di prossimità induttivi
Detectores de proximidade indutivos
Listing and Certification :
Applicable on proximity switches bearing the
UL and CSA marks only.
Enclosure : Type 12, 4X indoor use only
Overcurrent protection *
Conductor size Maximum
AWG mm
2
Ampere rating
20 0.5 5
22 0.34 3
24 0.22 2
26 0.11 1
28 0.08 0.8
* Required on product references with termination
number 230 - 8 mm plastic units shall be installed with
mounting clamp type XSZ-B. For connector version, a
suitable UL and CSA Approved connector must be used
e1
e3
e2
XS•-M
XS•-M•••••••D/K/A/B/C/G/T
d1
h
a
b
c
BN Brown Brun Braun Marrón Marron Castanho
BU Blue Bleu Blau Azul Blu Azul
BK Black Noir Schwarz Negro Nero Preto
WH White Blanc Weiß Blanco Bianco Branco
RD Red Rouge Rot Rojo Rosso Vermelho
GN Green Vert Grün Verde Verde Verde
–/+
+/–
BN/1
BU/2
–/+
+/–
BN/1
BN/3
BU/4
BU/3
+
BK/4 = NO
BK/2 = NC
PNP
BN/1
BU/3
+
BK/4 = NO
BK/2 = NC
NPN
BN/1
BU/3(NO), BN/1(NC)
+
WH/2
PNP
BN/1(NO), BU/3(NC)
BK/4
BU/3(NO), BN/1(NC)
+
WH/2
NPN
BN/1(NO), BU/3(NC)
BK/4
Indication XS•-M•• XS•-M••M•250
Signalisation NO NC NO NC
Funktionsanzeige
Señalización
Segnalazione
Sinalização
Mechanical installation
Mise en œuvre mécanique
Mechanische Installation
Instalación mecánica
Messa in opera meccanica
Instalação mecânica
* Increased range model
Portée augmentée
Erhöhter Schaltabstand
Alcance aumentado
Portata maggiorata
Alcance aumentado
T (Nm)
S
10 cm
c
c
+
R
+
XS•-M••M•23•
RD
GN
RD
GN
RD
GN
RD
GN
Disconnect when short circuit
Débrancher sur court-circuit
Bei Kurzschluß abschalten
Deconectado quando cortocircuito
Scollegato su corto-circuito
Desligar quando curto-circuito
RD
GN
(mm) Sn a b c D/K A B C G T S T (Nm) e1 e2 e3 d1 h x
M8x1 1,5 50 40 61 –––– 13 5 3 18 4,5 8 0 0
M12x1 2/*4 50 42 61 –––– 17 15 4/*8 24/*48 6/*12 12 0 0
M18x1 5/*10 60 51,5 70 75 106 74 75 95 24 35 10/*20 60/*120 15/*30 18/*28 0/*1,8 0/*1,8
M30x1,5 10/*20 60 51,5 70 75 106 71 75 87 36 50 20/*40 120/*240 30/*60 30/*50 0/*6 0/*6
M8x1 2,5 50 36 4 61 –––– 13 5 10 30 7,524 5
M12x1 4 50 37 5 61 –––– 17 15 16 48 12 36 8
M18x1 8 60 43,5 8 70 75 106 74 75 95 24 35 32 96 24 54 16
M30x1,5 15 60 38,5 13 70 75 106 71 75 87 36 50 60 180 45 90 30
h
10 cm
h
page 2/2
x
TENSION DANGEREUSE
Couper l'alimentation avant
de travailler sur cet appareil.
Une électrocution
entrainera la mort ou
des blessures graves.
TENSION PELIGROSA
Desenergice el equipo
antes de realizarle servico.
Una descarga eléctrica
podrá causar la muerte
o lesiones serias.
HAZARDOUS VOLTAGE
Disconnect all power
before servicing equipment.
Electric shock will result
in death or serious injury.
DANGER / PELIGRO / DANGER
z
z
BN
BU
z
z
BN
BU
XUZ-E08
Electrical installation XS•-M••P•37• XS•-M••KP340/KPM40 XS•-M••DA210/211/214 XS•-M••M•230*/239* XS•-M••M•250
Mise en œuvre électrique
Elektrische Installation
Instalación eléctrica
Messa in opera elettrica
Instalação elétrica
XS•-M••N•37• XS•-M••DB210/211 * Without short circuit protection
Non protégés court-circuit
Ohne Kurzschlußschutz
No proteción cortocircuito
Non protetto corto-circuito
Não protecção curto-circuito
Voltage limits (1) a 10...58 V a 10...38 V a 10...58 V z 20...264 V
Load switching capacity (2) 0...200 mA 0...200 mA 1,5...100 mA Ø8: 5...100, Ø12: 5...200, Ø18/30: 5...200 a /5...300 c
Voltage drop (3) 2 V 2,6 V 4 V 5,5 V
Leakage current (4) –– 0,5 mA 1,5 mA(M•250), 0,6 mA(M•230), 0,8 mA(M•239)
Current consumption (5) 10 mA 10 mA, 15 mA (KPM)
(1) Limite de tension / Betriebsspannung / Límites de tensión / Limiti di tensione / Limites de tensão
(2) Courant commuté / Schaltstrom / Intensidad conmutada / Corrente commuta / Corrente comutada
(3) Tension de déchet / Spannungsfall (Ausgang durchgesteuert) / Tensión residual / Caduta di tensione / Tensão de defeito
(4) Courant résiduel / Reststrom (Ausgang gesperrt) / Intensidad residual / Corrente residual / Corrente residual
(5) Courant consommé / Leerlaufstrom / Intensidad consumida / Corrente consumata / Corrente consumida

Summary of content (2 pages)