Schneider Electric XW-MPPT-60 User Manual

Conext System Control Panel Menus
B–8 975-0400-01-01 Revision H
This manual is for use by qualified personnel only.
For a map of all solar charge controller configuration menus, see Figure B-7 on
page B–9.
Configurable settings are identified by the square brackets [ ] around the values
along the right side of the screen.
To select and change a configurable setting:
1. On the desired configuration menu, press the up arrow or down arrow button
to highlight the setting you want to change.
2. Press Enter to highlight the current value of the setting.
3. Press the up arrow or the down arrow button to change the value. Hold down
the button to scroll through a large range of values quickly.
The previously set value appears with an asterisk (*) beside it.
4. Press Enter to select the value.
5. If you have another setting to change, return to step 1.
Or
If you have no more settings to change, press Exit until the SCP displays the
desired screen or menu.
To restore solar charge controller default settings:
1. On the Configure menu, select Restore Defaults.
2. Press Enter.
Figure B-6 Configuration Menus (Basic)
Basic Settings
Device Info
[48.0V]
[Flooded]
[200Ah]
[100%]
[3-Stage]
MPPT60 01: Setup
Basic Settings
[Bulk]
[Off]
[Operating]
Meters
215W
2.1A 100.5V
210W
3.7A 57.4V
3.5Ah 0.20kWh
0.1kAh 5kWh
20C
Float
AuxOff
975-0400-01-01_Rev-H(XW-MPPT60-150).book Page 8 Thursday, November 23, 2017 11:48 AM