Schneider Electric XW-MPPT-60 User Manual

Viewing Operating Status
975-0400-01-01 Revision H 4–5
This manual is for use by qualified personnel only.
Table 4 - 3 Other Operation Screens
Display Description


Accumulated amp-hours and kilowatt-hours produced by
multiple solar charge controllers today. This screen
appears only when multiple solar charge controllers are
installed in a network.
 
 
Measured input power, voltage, and current.


Accumulated amp-hours and kilowatt-hours produced
today by the individual unit.


Time the unit has been producing power today, in hours,
minutes, and seconds.
 

This Status screen changes according to the state of the
solar charge controller.
Line 1: Charge stage and auxiliary output state (ON or
OFF). See “Charge Stages” on page 4–6.
Line 2: Dynamic text that changes depending on unit
state, warning or fault status, or equalization mode. See
“Dynamic Text” on page 4–7.
When equalizing, when a fault or warning is active, or
when input voltage is low, this screen replaces the top-
level default operation screen.


If a time source is available on the network (for example if
a Conext System Control Pane (SCP), Conext XW+
inverter/charger, or Conext ComBox is on the Xanbus
network), this screen will be showing the clock time that
the unit entered Float (in hh:mm:ss and 24 hour format). If
no time source is available on Xanbus, this screen, will
show the value that the Time Online counter was at when
the unit transitioned to Float.
This screen is only visible if the unit is either in float, or is
not charging and the charge algorithm is set for 3-stage
(not set for No Float charging). If the unit is in bulk,
absorb, no float, or equalize, this screen is hidden.


This screen displays the elapsed time that the unit has
been in float in hh:mm:ss format.
This screen is only visible if the unit is either in float, or is
not charging and the charge algorithm is set for 3-stage
(not set for No Float charging). If the unit is in bulk,
absorb, no float, or equalize, this screen is hidden.

User-defined custom screen text (configured on the
Display Menu). This screen only appears if it has been
configured.