Schneider Electric Owner's Guide

Configuration
2–4 975-0560-01-01 G
Configuring Battery Characteristics and Battery Charging
From various menus in the SCP you can:
Enable battery equalization.
Configure your battery type, voltage, and amp-hour capacity.
Configure a custom battery type by adjusting settings for each battery
charge stage and fine-tuning temperature-compensated charging.
Monitor battery temperature.
Table 2-1 describes the settings available for the charge controller’s battery
configuration.
WARNING
HAZARD OF FIRE AND EXPLOSION
Battery charging settings must be configured by qualified personnel in
accordance with the battery manufacturer's recommended charging
instructions.
Failure to follow these instructions can result in death or serious injury.
NOTICE
BATTERY DAMAGE
The charge controller is incapable of determining battery type and cannot
warn against or disallow incorrect settings. Carefully check the settings for
bulk, absorption, float, and equalization charge against the battery
specifications. Incorrect settings can damage the battery or shorten battery
life.
Failure to follow these instructions can result in equipment damage.
Table 2-1 Battery configuration settings
SCP Device Menu
Item Setting Values Default Description
Setup Equalize Disabled
Enabled
Disabled Enables or disables battery
equalization. If the battery type
is set to GEL or AGM, this
setting is not displayed.
Advanced Settings >
Multi Unit Config >
Connections
DC Conn BattBank1...Batt
Bankx
BattBank1 Sets the battery bank
connected to the charge
controller. This is important for
networked installations where
multiple devices must
coordinate their activity around
common DC connections.
975-0560-01-01(XW-MPPT80-600_Ops).book Page 4 Wednesday, November 22, 2017 5:52 PM