Schneider Electric Owner's Guide
Configuration
2–10 975-0560-01-01 G
Configuring Peak Power Tracking
You can disable automatic maximum power point tracking and fix the reference
voltage level at which the charge controller operates the array. Fixing the array
operating reference voltage is not required for normal operation, but it can be
useful for testing purposes.
Table 2-3 Peak power tracking settings
SCP Device Menu
Item Setting Values Default Description
Advanced Settings >
Input Settings
MPPT AutoTrack Disabled
Enabled
Enabled Enables or disables MPPT.
Advanced Settings >
Input Settings
MPPT Ref Volts 195–600V N/A When tracking is set to
Disabled, you can select the
reference voltage from which the
charge controller operates. When
tracking is set to Enabled, the
reference voltage updates to
reflect tracking activity.
Advanced Settings >
Multi Unit Config >
Connections
PV In SolarArray
1–16
SolarArray1 Sets the input connection for the
charge controller.
975-0560-01-01(XW-MPPT80-600_Ops).book Page 10 Wednesday, November 22, 2017 5:52 PM