Schneider Electric Owner's Guide
Configuring the Auxiliary Output
975-0560-01-01 G 2–11
Configuring the Auxiliary Output
Use the Aux Settings menu item to enable and configure the auxiliary output.
You can use the auxiliary output to operate a relay, indicator light, vent fan, alarm,
or any other required function. See “Auxiliary Output Functions” on page 1–9. For
configurable trigger sources, you can define trigger level, trigger delay, clear
level, and clear delay settings. Non-configurable trigger sources include errors,
warnings, and faults.
To display the Aux menu auxiliary settings, select Advanced Settings > Aux
Settings.
Table 2-4 Aux menu settings
Setting Values Default Description
Manual Aux ManualOff
ManualOn
Automatic
ManualOff Sets the operating mode for the auxiliary output. When
set to Automatic, the auxiliary output will operate
according to the selected trigger source. You can
toggle the auxiliary relay between NC and NO at any
time by selecting ManualOn or ManualOff.
Note: The remaining settings in this table are only visible when Manual Aux is set to Automatic.