Schneider Electric Owner's Guide
Configuring the Auxiliary Output
975-0560-01-01 G 2–13
Trigger
Delay
0–600s 1s Sets how long—in seconds—the selected trigger
source must be active before the auxiliary output
activates. This can avoid unnecessary triggering by
momentary loads.
This setting is hidden if the trigger source is set to an
error, warning, or fault.
Clear Level Depends on Trigger Source
(see Table 2-5)
Sets the battery or array voltage to turn off the auxiliary
output. If the selected trigger source is HighBattTemp,
LowBattTemp, or HighHsTemp, this screen displays
Clear Temperature Level in degrees Celsius.
This setting is hidden if the trigger source is set to an
error, warning, or fault.
Clear Delay 0–600s 1s Sets how long—in seconds—the trigger condition must
remain inactive before the auxiliary output turns off.
This setting is hidden if the trigger source is set to an
error, warning, or fault.
NOTE
If the selected trigger source is LowBattV or HighBattV, changing the Batt
Voltage setting will reset the Trigger Level and Clear Level settings to
their default values
Table 2-4 Aux menu settings
Setting Values Default Description
975-0560-01-01(XW-MPPT80-600_Ops).book Page 13 Wednesday, November 22, 2017 5:52 PM