Schneider Electric Owner's Guide
Viewing Status on the Conext System Control Panel
975-0560-01-01 G 3–3
Viewing Status on the Conext System Control Panel
Use the Conext System Control Panel (SCP) to configure and view system
information and operating status. See Appendix B, “Conext System Control Panel
Menus” for an overview of the SCP, or see the SCP Owner’s Guide (Document
Part Number 975-0298-01-01).
• When in Charge Control mode the SCP displays parameters such as PV
voltage, battery voltage, and charge current on the XW MPPT80 Home
screen.
• When a fault or error condition exists, the SCP Fault/Warning light is solid,
and the SCP shows Fault Active on the XW MPPT80 Home screen.
• When a warning condition exists, the SCP Fault/Warning light is flashing, and
the SCP shows Warning Active on the XW MPPT80 Home screen.
Normal Operation
From the XW MPPT80 Setup screen, select Meters to view normal operation
information. This information is refreshed once per second.
Equalize
(Orange)
• Solid when an equalize charge has been enabled via the SCP
but has not yet started (the charge controller must complete a
full bulk and absorption cycle before it can begin the equalize
cycle).
• Flashing at a constant rate when the charge controller is
performing the equalize charge to the batteries. After the
equalize charge has completed, the LED goes dark.
Table 3- 1 Charge controller status LEDs
LED Description
Table 3-2 Normal operation information (Meters screen)
Display Description
PV In Power Measured input power.
PV In Measured input voltage and current.
DC Out Power Power being produced by the charge controller now.
DC Out Measured output voltage and output current.
Time in Float
00:00:00
Elapsed time that the charge controller has been in float in hh:mm:ss format.
Today Accumulated amp hours and kilowatt hours produced today by the charge
controller.
Life Lifetime accumulated amp hours and kilowatt hours produced by the charge
controller.
Batt Temp Battery temperature detected by the BTS. If a BTS is not connected, then no
value is shown.