Schneider Electric Owner's Guide

Specifications
A–6 975-0560-01-01 G
Output Power Versus Ambient Temperature
Once the charge controller’s heat sink reaches maximum full-power operating
temperature, the charge controller reduces its power output to ensure
component ratings are not exceeded.
Accessories
The Conext System Control Panel (SCP) (Part Number 865-1050) is required for
installation of the charge controller and is strongly recommended for ongoing
operation.
As the primary interface to the charge controller, the SCP is used for setup and
configuration. Once installation is complete, you can use the SCP for monitoring
and fault reporting. Only one SCP is required to monitor multiple charge
controllers.
In place of the SCP, the Conext ComBox (Part Number 865-1055) can also be
used. The ComBox allows you to configure and monitor the charge controller
through a web interface on a PC or laptop. See the Conext ComBox Owner’s
Guide (Document Part Number 975-0679-01-01)
Figure A-4 Output power vs. ambient temperature
2000
1000
4800
65
4000
3000
Ambient Temp (°C)
in Still Air
Maximum Output Power (W)
-10 0 10 20 30 40 50 60-20
45
NOTE
You must use the SCP with firmware version 1.05.00 or higher for full compati-
bility with the charge controller. For information on updating your firmware,
contact customer service. The Conext Config Tool or ComBox is required for
upgrading.