Schneider Electric Owner's Guide

Conext System Control Panel Menus
B–6 975-0560-01-01 G
The Setup Menu
The Setup menu allows access to the Meters screen and several other
commands that control the charge controller’s operation.
Figure B-4 Setup menu
Table B- 3 Setup menu
Menu Item Description
Meters Displays the Meters screen.
Harvest Logs Displays the charge controller’s daily, monthly, and yearly
performance logs. See “Viewing Harvest Logs” on page 3–12.
Force Chg Causes the current charge stage to change to the selected
stage.
Equalize Starts or stops battery equalization.
Mode Sets the charge controller’s operating mode.
Clear Faults
Warnings
Clears any active faults or warnings. If the fault or warning
condition is still present, the fault or warning message could
reappear.
View Device
Info
Displays the Dev Info screen. On the Dev Info screen you
can view the warning, fault, and event logs.
Basic
Settings
Displays the charge controller’s basic or advanced
configuration settings. To change to advanced settings, press
the Enter, up arrow, and down arrow buttons simultaneously.
XW MPPT80 01: Setup