Installation Guide

1
www.SEsolar.com
D1 Installation – Mounting
D Installation – Specifications
B Introduction
A
B
C
D
E
F
G
H
Quick Start Guide
C Tools and Equipment
A
B
C
AC (grid) terminals (L1, L2)
AC Neutral bus bar
AC Ground bus bar
C
D
F
B
A
H
G
E
~32in
800mm
between
Prewired
Systems
between
other
objects
~24in
600mm
208.4 LBS
94.5 KG
90°
90°
upright
HAZARD OF CRUSH INJURY AND EQUIPMENT DAMAGE
At least two people are required to lift this equipment. Use of appropriate lift equipment is
recommended.
• Lift equipment must be able to support a minimum of 208.4 lbs (94.5 kg).
• For structural and seismic stability, this equipment must be mounted onto a vertical
supporting surface strong enough to support a minimum of 690 lbs (313 kg), and with
mounting hardware that can also support this weight.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
3
Mount
2
4
Fasten backplate screws
(3/8 in screws, not supplied)
1
Mark and predrill the wall into
three studs, 16 in (406 mm) apart.
Battery+ and Battery- terminals
Chassis ground terminals
D
E
B
D
A
E
C
B1 Introduction – Wiring Connections
For Indoor Use Only.
~24in
600mm
~24in
600mm
Attach screw-in handles and/or attach
lifting rings (not supplied) to the two
“D” holes at each top corner.
NOTE: All components except the lift handles are supplied pre-assembled.
A
Safety Information
Exclusion for Documentation
UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER
(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER
DOCUMENTATION;
(
B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL,
WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USERS RISK; AND
(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE
TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW.SCHNEI-
DER
-ELECTRIC.COM.
Important Information
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install,
operate, service or maintain it. The following special messages may appear throughout this documentation or on the
equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
Please Note
Electrical equipment should be installed, operated, serviced, and maintained only by
qualified personnel. No responsibility is assumed by Schneider Electric for any
consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to
the construction, installation, and operation of electrical equipment and has received safety training to recognize and
avoid the hazards involved.
A
Section
Step
A
Label
Safety
Direction
Expand
The addition of either symbol to a “Danger” or
“Warning” safety label indicates that an electrical
hazard exists which will result in personal injury
if the instructions are not followed.
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid
possible injury or death.
WARNING indicates a hazardous situation which, if not avoided,
can result in death or serious injury.
DANGER indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Conventions Used
Contact Information
Schneider Electric Solar Inc.
3700 Gilmore Way, Burnaby B.C., V5G 4M1, Canada
https://solar.schneider-electric.com/
Submit your support request online at: https://solar.schneider-electric.com/tech-support/netsuite/
24in
610 mm
36in
914mm
• Personal protective equipment (PPE)
• Voltage meter
• Locks and tags
• Screwdriver and drill set (powered and manual)
• 3/8 in mounting screws (x6)
The following materials and tools are not supplied but are required to complete the
installation:
• Motorized hand trucks and/or portable
crane system
• Cable crimper
• Cable cutter
The Conext Quick Fit XW Pro consists of an Inverter/Charger and a selection of Conext
solar accessories that are designed to be an integral part of any utility grid-connected PV
Power System. The Conext Quick Fit XW Pro is preassembled on a backplate for quick and
easy installation.
Conext™ Quick Fit XW Pro
865-6848-21QF
975-0993-01-01
05-2019
Conext Gateway
Conext Battery Monitor
Conext System Control Panel
Conext XW Pro 6848 Inverter/Charger
Conext XW Pro Mini Power Distribution Panel
Mounting holes x 6
Backplate
Lift handles x4
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
This document is in addition to, and incorporates by reference, the relevant product manuals for
each individual device on the Conext Quick Fit XW Pro. Before reviewing this document, you must
read the relevant product manuals. Unless specified, information on safety, specifications,
installation and operation is as shown in the primary documentation for each device. Ensure you
are familiar with that information before proceeding.
Failure to follow these instructions will result in death or serious injury.
NOTE: The Network Terminators are located on the Conext Gateway and Conext Battery Monitor.

Summary of content (2 pages)