The numeric display screen shows the following information about the operational state
of the Conext XW Pro:
n
Output power in kilowatts (when the (kW) LED is lit).
n
Battery charger current in Amps (when the (A) charging LED is lit).
n Stb when the Conext XW Pro is in Standby mode.
n Sch when the Conext XW Pro is in Search mode.
n OFF when the STARTUP/SHUTDOWN button is pressed and held for five seconds. OFF
is displayed briefly before the unit turns off.
n --- appears when the Conext XW Pro is in transition between modes, when inverter
selection is disabled via the Conext Gateway, or operating in AC passthrough mode.
n En appears momentarily when the Conext XW Pro is enabled.
n dIS appears momentarily when the Conext XW Pro is disabled.
n 5 minute countdown timer value may appear if there is no other more significant
information to display after grid interruption during energy export operation.
Monitoring Operation with the Conext Gateway
The Conext Gateway provides remote configuration and monitoring capability for the
Conext XW Pro and all other Xanbus-enabled devices in the network via its browser-
based web application. It is the primary and recommended way to monitor operations of
all networked devices.
Accessing the Device in the Web Application
Refer to Logging in to the Conext Gateway Web Application in the Conext Gateway
Owner’s Guide to gain access to the web application. If connectivity between system
components are working, networked Conext XW Pro units can be accessed by clicking
the device icon in the Dashboard screen, or its instance under the Devices menu.
Status Page
The Conext XW Pro Status page displays real-time operational data specific to the
selected Conext XW Pro instance. In Tables 2 and 3 are all possible states that can be
shown for Inverter Status and Charger Status.
Monitoring Operation Conext XW Pro Owner's Guide
990-91227A-01 This document is intended for use by qualified personnel 41