Installation Guide
2-16 975-0691-01-01 Revision B
Mounting the Shunt
The shunt connects between the inverter and batteries in the negative (–) battery
power wire.
To mount the shunt:
1. Mount the shunt on or near the battery enclosure close to the negative (–)
battery terminal. If possible, install the shunt inside your battery enclosure.
Use appropriate screws to secure the shunt to the battery enclosure.
Electrical Wiring
The Battery Monitor bottom cable connections consist of five ports, Battery
Analog Signal, two Xanbus cables, BTS, RS-485. A network terminator is
provided for installation where only one Xanbus Port is in use.
NOTICE
EQUIPMENT DAMAGE
The shunt must be installed in the negative line. Installing the shunt in the
positive line may result in damage to the Battery Monitor.
Failure to follow these instructions can result in damage to equipment.
Figure 2-8 Mounting the shunt