Fault Reference Table
Table 5-2 Fault Reference Table
Fault
number Message
Message
(translation) Type Cause Action
F250 System clock
not set. Set
correct time.
Manual On initial startup,
the clock needs
to be set. The
system will not
operate correctly
until it is.
Set the clock to the
correct time. See
“Using the Clock
Menu” on page 3–12.
F251 A device is
lost. Check
connection.
Manual The Xantrex XW
SCP has lost
communications
with another
device on the
network.
Check network
connection between
the Xantrex XW SCP
and the device.
F252 New device
detected.
Check device
settings.
Manual You have
connected a new
device to the
network or
reconnected a
disconnected
device.
Acknowledge the
message and check
that the device is
properly configured.
F500 Internal
failure.
Service
required.
Manual The silicon serial
ID number has
failed and the
Xantrex XW SCP
has gone into
Standby mode.
Reset the Xantrex XW
SCP by removing and
restoring network
power. If problem
persists, call customer
service.
F501 Memory
failure.
Service
required.
Manual The Xantrex XW
SCP has suffered
a non-volatile
memory failure.
Reset the Xantrex XW
SCP by removing and
restoring network
power. If problem
persists, call customer
service.