Installation Guide

975-0709-01-01 Revision C
05-2015
1
solar.schneider-electric.com
Conext XW+ Power Distribution Panel Installation Guide
865-1015-01 | 865-1014-01
*
Contact Information
solar.schneider-electric.com
Please contact your local Schneider Electric Sales Representative or visit the Schneider Electric website at:
http://solar.schneider-electric.com
A
Important Safety Information
A
Important Safety Infomation
B
Materials List
Conduit Box for routing cables to the PDP
Mounting Plate
2 x #4/0 AWG (107 mm²)
DC battery cables
*5 x #6 AWG (13.3 mm²)
cables for AC connections:
L1, L2, Neutral (labelled)
*1 x #2 AWG (33.6 mm²)
cable for grounding (labelled)
PDP enclosure with cabinet
door and removable upper and
lower faceplates
1 x GJ 250A 160 VDC,
3/8" stud DC breaker
*3 x 2-pole, 60 Amp 120/240 VAC
breakers (Square D QOU260) and
bypass lever
Surge arrestor rail and
mounting hardware
Other mounting hardware:
3 x #10 screws
3 x plastic bushings
Plastic cable ties
Label sheet
Factory Installed Components
Installer Provided Tools and Materials:
Phillips head screwdriver
Socket wrench
Level
Wall fasteners for mounting the PDP
Screws for wall mounting the Conduit Box
Hardware for additional wall mount bracket
Installer Provided AC Breakers:
*Applies to PDP model 865-1014-01 only
Fits DIN Rail (35 mm)
Connecting Conext MPPT Solar Charge Controllers to the PDP
Additional DC breakers are required for connecting MPPT 60 150 and MPPT 80 600 solar
charge controllers to the PDP. Contact Schneider Electric customer service for the number
of DC breakers needed for your system.
DC breaker master packs for Conext solar charge controllers are available from Schneider
Electric:
100, 125VDC Breaker Master Pack (865-1080) for MPPT 80 600 output, battery side
80A, 125 VDC Breaker Master Pack (865-1070) for MPPT 60 150 output, battery side
60A, 160VDC Breaker Master Pack (865-1075) for MPPT 60 150 input, PV array side
*NOTE: AC breakers (3x QOU260) and AC cables
(#6 and #2 AWG) are not included with model
865-1014-01.
This Guide is intended for anyone who needs to operate, configure, and troubleshoot the Conext XW+
Inverter/Charger. Certain configuration tasks should only be performed by qualified personnel in consultation with your
local utility and/or an authorized dealer. Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel. Servicing of batteries must only be performed or supervised by qualified personnel with
knowledge of batteries and their required precautions.
Qualified personnel have training, knowledge, and experience in:
Installing electrical equipment
Applying applicable installation codes
Analyzing and reducing the hazards involved in performing electrical work
Installing and configuring batteries
Selecting and using Personal Protective Equipment (PPE)
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E
or CSA Z462.
This equipment must only be installed and serviced by qualified electrical personnel.
Never operate energized with covers removed
Energized from multiple sources. Before removing covers identify all sources, de-energize, lock-out, and tag-out
and wait 2 minutes for circuits to discharge
Always use a properly rated voltage sensing device to confirm all circuits are de-energized.
Failure to follow these instructions will result in death or serious injury.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Batteries can present a risk of electric shock and high short-circuit current. The following precautions must be
observed when working with batteries:
Remove watches, rings or other metal objects.
Use tools with insulated handles.
Wear protective glasses, gloves and boots.
Do not lay tools or other metal parts on top of batteries.
Disconnect the charging source prior to connecting or disconnecting battery terminals.
Failure to follow these instructions will result in death or serious injury.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Battery Circuit Breakers must be installed according to the specifications and requirements specified by
Schneider Electric.
Servicing of batteries must only be performed by qualified personnel and the required precautions. Keep
unqualified personnel away from batteries.
Failure to follow these instructions will result in death or serious injury.
1. Before using the inverter, read all instructions and cautionary markings on the unit, the batteries, and all
appropriate sections of this manual.
2. Use of accessories not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or
injury to persons.
3. The inverter is designed to be permanently connected to your AC and DC electrical systems. The manufacturer
recommends that all wiring be done by a certified technician or electrician to ensure adherence to the local and
national electrical codes applicable in your jurisdiction.
4. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not
undersized. Do not operate the inverter with damaged or substandard wiring.
5. Do not operate the inverter if it has been damaged in any way.
6. This unit does not have any user-serviceable parts. Do not disassemble the inverter except where noted for
connecting wiring and cabling. See your warranty for instructions on obtaining service. Attempting to service the
unit yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is
disconnected.
7. To reduce the risk of electrical shock, disconnect both AC and DC power from the inverter before attempting any
maintenance or cleaning or working on any components connected to the inverter. Putting the unit in Standby
mode will not reduce this risk.
8. The inverter must be provided with an equipment-grounding conductor connected to the AC input ground.
9. Do not expose this unit to rain, snow, or liquids of any type. This product is designed for indoor use only. Damp
environments will significantly shorten the life of this product and corrosion caused by dampness will not be
covered by the product warranty.
10. To reduce the chance of short-circuits, always use insulated tools when installing or working with this equipment.
11. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with electrical
equipment.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
DANGER
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
WARNING
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
CAUTION
NOTICE is used to address practices not related to physical injury.. The safety alert symbol shall not be used with
this signal word.
NOTICE
Read and Save These Instructions - Do Not Discard
This guide contains important safety instructions for the Conext XW+ Inverter/Charger that must be followed during
installation procedures. Read and keep this Installation Guide for future reference.
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install,
operate, service or maintain it. The following special messages may appear throughout this bulletin or on the
equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists
which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
The Conext XW+ Power Distribution Panel may not be available in all regions; installation is dependent upon your
local electrical code. Consult your local electrical authority to ensure your installation is code-compliant.
NOTICE
Power Distribution Panel (PDP)
and parts for connecting to the
Conext XW+ inverter/charger