User Manual

DC Breaker Accessories
© 2020 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries
SAS or its aliated companies. All information is preliminary and will need to be conrmed at the time of order.
DS20200504_XW PDP.indd
XW Series Power Distribution | 6
Example XW Power Distribution
Congurations
The following table shows example ordering information for some typical configurations. Other configurations are also
possible such as adding additional MPPT charge controllers or integrating PV with AC Coupling. Please refer to the
Mini-PDP, PDP, and other product specifications and manuals for more information.
Compatible with XW Power Distribution Panels.
Single Unit Part
Number
Masterpack
Part Number
Masterpack
Qty
Application
Battery Disconnect/Breaker
250A, 160VDC, Panel Mount
DC Breaker
865-DCBRK-250 865-1065 6 units XW inverter connection to battery
Charge Controller Breakers
125A, 125VDC, Panel Mount
DC Breaker
865-DCBRK-125
- -
MPPT 100 600 output connection to
battery
100A, 125VDC, Panel Mount
DC Breaker
865-DCBRK-100 865-1080 12 units MPPT 80 600 output connection to battery
80A, 125VDC, Panel Mount
DC Breaker
865-DCBRK-80 865-1070 12 units MPPT 60 150 output connection to battery
60A, 160VDC, Panel Mount
DC Breaker
865-DCBRK-60 865-1075 48 units
MPPT 60 150 input connection to PV
array. Not used when the MPPT 60 150 is
installed with MPPT Disconnect RS
Part Number
1 XW 120/240V
1 MPPT
2 XW 120/240V
2 MPPT
3 XW 120/240V
3 MPPT
3 XW 3-phase
3 MPPT
XW Pro or
XW+
865-6848-21 or
865-6848-01
1 2 3 3
1
MPPT 100 600 or
MPPT 80 600
865-1032 or
865-1034
1 2 3 3
Optional: MPPT Disconnect RS
865-1036 and
865-1039
1
1
1
1
2
1
2
1
XW Mini PDP 865-1013-01² 1
XW PDP with AC Breakers 865-1015-01
2
1 1
XW PDP without AC Breakers 865-1014-01 1
XW Connection Kit 865-1020-02 1 2 2
60A 120/240 VAC Breaker Kit 865-1215-01
2
1 1
60A Three Phase Breaker Kit 865-1315-01
2
1
Charge Controller Output
Breaker
Refer to
DC breaker
accessories
1 2 3 3
Optional: Extra AC Breakers
for Generator Integration
Refer to
AC breaker
accessories
One 2-pole Two 2-pole Three 2-pole One 3-Pole
Manual Bypass Included
Included with
865-1215-01
Installed externally
(not included)
Included with
865-1315-01
1
XW+ must be used for three-phase applications
2
For IEC markets, substitute the PDP without AC Breakers (865-1014-01), and refer to compatible AC breaker accessories.