Configuring Split Phase Master and Slave Devices
If you chose to configure a split-phase system, the Split Phase Unit Assignment
window appears. There are two ways of configuring a split phase system. Either
assigning multiple single phase units into a split phase configuration, or using
split phase units and configuring one Conext XW+ as master and the rest of the
split phase units as slaves. Depending on how your system was installed and
which firmware version is running, you will see either the window in Figure 2-9 or
Figure 2-10 to initiate split phase configuration.
To configure split-phase units:
d) Drag and drop the unit that you want to be the system master into the
empty master box. If the units are installed as Single Phase (Figure 2-10)
you will be allowed to select a master unit for each phase.
e) Drag and drop the remaining devices into the slave boxes. When
dragging and dropping a unit the display on the front panel will flash to
indicate what device has been selected. You will not be able to proceed
to the next step of the wizard unless all devices have been assigned as
master or slave.
Figure 2-9 Split Phase Unit Assignment Window (Split Phase Units)