Conext Configuration Tool Manual

Using the Configuration Wizard
975-0720-01-01 2–27
This manual is for use by qualified personnel only
12. Set the XW Solar Charge Controller Input Settings.
The input settings allow you to disable automatic maximum power point tracking
and configure the reference voltage level the Conext MPPT Charge Controller
operates from. Configuring the reference voltage is not required for normal
operation, but can be useful for non-PV applications or for testing purposes.
13. Save the System Configuration. See “Save the System Configuration.” on
page 2–16 for details.
Equalization
Support
Enables or disables the ability to enter an equalization cycle. Refer to the battery
manufacturer’s specifications to determine whether equalization is recommended.
Equalization
Voltage
Selects the equalization voltage. Consult your battery manufacturer for equalization
voltage setting.
Bulk Voltage Sets the bulk voltage for a custom battery type.
Absorption
Voltage
Sets the absorption voltage for a custom battery type.
Float Voltage Sets the float voltage for a custom battery type.
Battery
Temperature
Compensation
Battery temperature compensation for a custom battery type. This setting is the
reference that the battery temperature sensor uses to adjust the charging voltage
when the temperature falls above or below 25 °C.
Table 2-10 XW Solar Charge Controller Custom Battery Settings
Setting Description
Figure 2-28 Setting the XW Solar Charge Controller Input Settings
Table 2-11 XW Solar Charge Controller Input Settings
Setting Description
Maximum Power
Point Tracking
Enables (Auto) or disables (Manual) MPPT.
Static Reference
Voltage
Selects the reference voltage the Charge Controller operates from when tracking is
set to Manual.