Conext Configuration Tool Manual

Device Configuration
3–26 975-0720-01-01
This manual is for use by qualified personnel only
Advanced Features
MPPT 80 600 only: The Advanced Features menu allows you to access the advanced features of the
MPPT 80 600.
Saving and Loading Configurations
Save Configuration allows you to save the current configuration of the Solar
Charge Controller. Restore Configuration allows you to load a previously saved
configuration from a file.
Output Level Selects the active high auxiliary output voltage (the active low output voltage is 0 V).
Trigger
Source
Selects the desired condition (Trigger Source) to activate the auxiliary output.
Trigger Level Selects the battery or array voltage to activate the auxiliary output. If the selected
Trigger Source is Batt Temp High, Batt Temp Low, or Heat Sink Temp High, this screen
displays Trigger Level in degrees Celsius.
Trigger Delay Selects how long the selected trigger source must be active before the auxiliary output
activates. This can avoid unnecessary triggering by momentary loads.
Clear Level Selects the battery or array voltage to turn off the auxiliary output. If the selected Trigger
Source is Batt Temp High, Batt Temp Low, or Heat Sink Temp High, this screen displays
Clear Level in degrees Celsius.
Clear Delay Selects how long the trigger condition must remain inactive before the auxiliary output
turns off.
Table 3-10 Auxiliary Menu Settings (Items in Gray Displayed When Auxiliary Output Mode Is Set to
“Automatic”)
Setting Description
Figure 3-24 Advanced Features (MPPT 80 600 Only)