Product Manual

Default Settings
B–4 975-0240-01-01
LithiumIon Submenu
AC Menu
Batt Temp Comp
a
108 mV/C (Flooded,
Gel)
84 mV/C (AGM)
0–180 mV/C 1
a.Custom battery default settings are based on the Flooded battery default set-
tings. The Gel and AGM default settings are provided here for reference only.
Item Default Setting Range Step Size
Control
EXT_BMS EXT_BMS, 3stage,
2stage NoFloat
n/a
Bulk Voltage 57.6 V 54.2–64.0 V 0.1
Max Bulk Current 140 A 10-140 A 1
Abs Voltage 57.6 V 40.0–64.0 V 0.1
Max Abs Current 140 A 10-140 A 1
Float Voltage 54.0 V 50.0–64.0 V 0.1
Max Float Current 140 A 1-140 A 1
DisChglmax 150% 20-500% 1
DisChglmax Timer 10 sec 0-300 sec 1
Item
Default Setting Range
Step Size
120
VAC
240
VAC
120
VAC
240
VAC
AC Priority AC1 AC1, AC2 n/a
AC1 Breaker 60 A 3–60 A 1
AC1 Lo Volt 106 V 212 V 78–115 V 156–230 V 1
AC1 Hi Volt 132 V 264 V 125–140 V 250–280 V 1
AC1 Lo Freq 55 Hz 44–59 Hz 1
AC1 Hi Freq 65 Hz 61–70 Hz 1
AC2 Breaker 60 A 3–60 A 1
AC2 Lo Volt 80 V 160 V 78–115 V 156–230 V 1
AC2 Hi Volt 138 V 276 V 125–140 V 250–280 V 1
AC2 Lo Freq 55 Hz 44–59 Hz 1
AC2 Hi Freq 65 Hz 61–70 Hz 1
Item Default Setting Range Step Size
XW_Operation.book Page 4 Wednesday, August 12, 2015 2:39 PM