Operating instructions

5
7. FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE
A SPARK NEAR THE BATTERY MAY
CAUSE A BATTERY EXPLOSION. TO
REDUCE THE RISK OF A SPARK NEAR
THE BATTERY:
7.1 Check polarity of battery posts. POSITIVE
(POS, P, +) battery post usually has a larger
diameter than NEGATIVE (NEG, N, –) post.
7.2 Attach at least a 24-inch-long 6-gauge
(AWG) insulated battery cable to
NEGATIVE (NEG, N, –) battery post.
7.3 Connect POSITIVE (RED) charger clip to
POSITIVE (POS, P, +) post of battery.
7.4 Position yourself and free end of cable as
far away from battery as possible – then
connect NEGATIVE (BLACK) charger clip
to free end of cable.
7.5 Do not face battery when making nal
connection.
7.6 When disconnecting charger, always do
so in reverse sequence of connecting
procedure and break rst connection
while as far away from battery as
practical.
7.7 A marine (boat) battery must be removed
and charged on shore. To charge it on
board requires equipment specially
designed for marine use.
8. GROUNDING AND AC POWER CORD CONNECTIONS
This battery charger is for use on a
nominal 120 volt circuit. The plug must
be plugged into an outlet that is properly
installed and grounded in accordance with
all local codes and ordinances. The plug
pins must t the receptacle (outlet). Do
not use with an ungrounded system.
DANGER: Never alter the AC cord or
plug provided – if it does not t the outlet,
have a proper grounded outlet installed
by a qualied electrician. An improper
connection can result in a risk of an
electric shock or electrocution.
NOTE: Pursuant to Canadian
Regulations, use of an adapter plug
is not allowed in Canada. Use of an
adapter plug in the United States is not
recommended and should not be used.
USING AN EXTENSION CORD
The use of an extension cord is not
recommended. If you must use an
extension cord, follow these guidelines:
Pins on plug of extension cord must be
the same number, size, and shape as
those of plug on charger.
Ensure that the extension cord is
properly wired and in good electrical
condition.
Wire size must be large enough for
the AC ampere rating of charger, as
specied:
Length of cord (feet) 25 50 100 150
AWG* size of cord 18 18 16 14
*AWG-American Wire Gauge
9. ASSEMBLY INSTRUCTIONS
9.1 Remove all cord wraps and uncoil the cables prior to using the battery charger.
10. CONTROL PANEL
LED INDICATORS
CLAMPS REVERSED (red) LED
ashing: The connections are reversed.
CHARGING (yellow/orange) LED
lit: The charger is charging the battery.
CHARGING (yellow)/orange LED
ashing: The charger is in abort mode.
CHARGED/MAINTAINING (green)
LED pulsing: The battery is fully charged
and the charger is in maintain mode.
NOTE: See the Operating Instructions
section for a complete description of the
charger modes.
DIGITAL DISPLAY
The display will show the battery
VOLTAGE when the charger is not
charging a battery. When it goes
into charging mode, the display will
automatically change to ON (to show
charging has started) and then show the
percent-of-charge of the battery being
charged and either 6 or 12 (the voltage of
the battery, determined by the charger). If
you manually stop the charging process
(by pressing the CHARGING RATE
button) before the battery is fully charged,
the display will show OFF.