Datasheet

1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
01
002
052
0031.7701.11
Circuit Protection
OMH 125
n/a
0031.7701.22
n/a
0031.7701.23
n/a
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
2 Type of change
Change of material
Modified label
3 Detailed description of change
The isolation material changes from a white LCP to a black coloured LCP. The new material fulfils the
glow wire requirements given in IEC60127-6:2014 and achieves reflow solderability acc. JEDEC J-
STD020E (No moisture sensitivity Level 1)
Old product appearance
New product appearance
Old product label
New product label
4 Reason of change
Product improvement to fulfil the enhanced glow wire requirements according to the updated standard
IEC 60127-6:2014. Further, the new insulation material reaches the best moisture sensitivity level of 1
acc. to JEDEC which enables an unlimited floor lifetime of the surface mount device.
5 Release date
The change will be rolled-out starting ww 05/2017 (date code 1705 or higher on label) and lasts a few
months depending on the variant and stock.
Please note the detailed overview of the already converted fuseholder variants which are produced and
approved using the new standard IEC 60127-6:2014
1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
01
002
052
0031.7701.11
Circuit Protection
OMH 125
n/a
0031.7701.22
n/a
0031.7701.23
n/a
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
2 Type of change
Change of material
Modified label
3 Detailed description of change
The isolation material changes from a white LCP to a black coloured LCP. The new material fulfils the
glow wire requirements given in IEC60127-6:2014 and achieves reflow solderability acc. JEDEC J-
STD020E (No moisture sensitivity Level 1)
Old product appearance
New product appearance
Old product label
New product label
4 Reason of change
Product improvement to fulfil the enhanced glow wire requirements according to the updated standard
IEC 60127-6:2014. Further, the new insulation material reaches the best moisture sensitivity level of 1
acc. to JEDEC which enables an unlimited floor lifetime of the surface mount device.
5 Release date
The change will be rolled-out starting ww 05/2017 (date code 1705 or higher on label) and lasts a few
months depending on the variant and stock.
Please note the detailed overview of the already converted fuseholder variants which are produced and
approved using the new standard IEC 60127-6:2014
owner
dislercy
creation date
2016-07-26
release date
2016-12-12
released by
nowakfr
change order no
2009098
rev
A
page
1 of 2
D10-006-925
Product Change Notification OMH material change