Datasheet

Table Of Contents
1
Power Entry Modules with Line Filter
DG12
https://www.schurter.com /PG06
EMC Products
IEC Appliance Inlet C14 with Filter, Circuit Breaker TA35 (recessed)
Screw-on with IP67 Screw-on A Screw-on B
See below:
Approvals and Compliances
C14
70° C
C18
70° C
Description
- Panel mount :
Screw-on or snap-in mounting from front side
- 3 Functions :
Appliance Inlet protection class I or II , Circuit breaker type TA35 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- IP67 protection
- Recessed rocker switch
- Various mounting options
- V-Lock cord retaining
Characteristics
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Other rocker marking
- Medical version M80
- Capacitance CX1
- Variants in white
- Filter version with high inductance
References
Alternative: version without line filter DG11
Weblinks
pdf data sheet, html data sheet, General Product Information,
Distributor-Stock-Check, Accessories, Detailed request for product,
Landing Page
Technical Data
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Tempe-
rature
-25 °C to 60 °C
Climatic Category 25/060/21 acc. to IEC 60068-1
IP-Protection from front side IP40 or IP65 / IP67 acc.
to IEC 60529
Protection Class Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness S Screw: max 8 mm
Mounting screw torque max 0.5 Nm
: S =1.0/1.2/1.5/2.0/2.5/3.0 mm
Material: Housing Thermoplastic, black, UL 94V-0
appliance inlet/-outlet C14 C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
2000 A
Line Filter Standard and Medical Version, IEC
60939, UL 60939-3, CSA C22.2 no. 8
Technical Details
MTBF > 100'000 h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-
ments by SCHURTER.

Summary of content (12 pages)