Datasheet

1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
02
006
016
See list below
Connectors
FKH
02
006
016
See list below
Connectors
FKHD
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
List of part numbers affected
3-103-553
4304.4044
4304.4060
4304.5038
4304.5048
4304.4001
4304.4045
4304.4081
4304.5039
4304.5049
4304.4002
4304.4046
4304.5001
4304.5040
4304.5050
4304.4003
4304.4047
4304.5002
4304.5041
4304.5052
4304.4004
4304.4048
4304.5003
4304.5042
4304.5053
4304.4005
4304.4049
4304.5004
4304.5043
4304.5054
4304.4030
4304.4050
4304.5005
4304.5044
4304.4041
4304.4056
4304.5031
4304.5045
4304.4042
4304.4057
4304.5036
4304.5046
4304.4043
4304.4059
4304.5037
4304.5047
2 Type of change
Backside of plastic flange with ribs and less material
IEC-Rating in plastic socket
3 Detailed description of change
Old product appearance
(backside only, not visible from front)
New product appearance
(backside only, not visible from front)
Old IEC-Rating
New IEC-Rating
4 Reason of change
To improve the moulding process and to avoid flow lines
Rating according IEC-Standard (same rating, new appearance)
5 Release date
The change takes effect in ww 19/2020 (Date code 2019 or higher on label).
1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
02
006
016
See list below
Connectors
FKH
02
006
016
See list below
Connectors
FKHD
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
List of part numbers affected
3-103-553
4304.4044
4304.4060
4304.5038
4304.5048
4304.4001
4304.4045
4304.4081
4304.5039
4304.5049
4304.4002
4304.4046
4304.5001
4304.5040
4304.5050
4304.4003
4304.4047
4304.5002
4304.5041
4304.5052
4304.4004
4304.4048
4304.5003
4304.5042
4304.5053
4304.4005
4304.4049
4304.5004
4304.5043
4304.5054
4304.4030
4304.4050
4304.5005
4304.5044
4304.4041
4304.4056
4304.5031
4304.5045
4304.4042
4304.4057
4304.5036
4304.5046
4304.4043
4304.4059
4304.5037
4304.5047
2 Type of change
Backside of plastic flange with ribs and less material
IEC-Rating in plastic socket
3 Detailed description of change
Old product appearance
(backside only, not visible from front)
New product appearance
(backside only, not visible from front)
Old IEC-Rating
New IEC-Rating
4 Reason of change
To improve the moulding process and to avoid flow lines
Rating according IEC-Standard (same rating, new appearance)
5 Release date
The change takes effect in ww 19/2020 (Date code 2019 or higher on label).
owner
huberth
creation date
01.04.2020
release date
01.04.2020
released by
blumhe
change order no
2019716
rev
B
page
1 of 2
D10-043-994
Product Change Notification PCN FKH/FKHD

Summary of content (2 pages)