Datasheet

1
POWER ENTRY MODULES WITHOUT LINE FILTER
K
K
D
D
www.schurter.com
KD
IEC Appliance Connector C14 with Fuseholder, Line Switch 1- or 2-pole and Voltage Selector
Standard or Medical Fuse drawer
C14
70° C
D
D
e
e
s
s
c
c
r
r
i
i
p
p
t
t
i
i
o
o
n
n
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 4 Functions:
Inlet Protection class I, Line switch 1- or 2-pole, Fuseholder with in-
terchangeable fuse drawer for Fuse-links 5 x 20 mm or 6.3 x 32 mm,
with or without voltage selector (step)
- Quick connect terminals 4.8 x 0.8 mm
- Alternative: version with line filter CD
C
C
h
h
a
a
r
r
a
a
c
c
t
t
e
e
r
r
i
i
s
s
t
t
i
i
c
c
s
s
- All single elements are already wired
- The fuse drawer "Fingergrip" can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
O
O
t
t
h
h
e
e
r
r
v
v
e
e
r
r
s
s
i
i
o
o
n
n
s
s
o
o
n
n
r
r
e
e
q
q
u
u
e
e
s
s
t
t
- Line switch, illuminated
- Line switch with other rocker marking
- Line switch 1-pole
- For protection class II
W
W
e
e
b
b
l
l
i
i
n
n
k
k
s
s
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
D
D
a
a
t
t
a
a
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 10 A / 125
VAC; 60 Hz
Dielectric Strength > 3 kVAC between L-N
> 4
kVAC between L/N-PE
(1
min/50 Hz)
Allowable Operation Temp. -25 °C to 70 °C
Degr
ee of Protection
fr
om front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 4.8 x 0.8 mm ,
tin-plated
Panel Thickness s Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold con-
dition) pin-temperature 70 °C, 10 A, Pro-
tection class I
Fuseholder 1 or 2 pole, Shocksafe category PC2 acc.
to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32
mm
Rated Power Acceptance @ T
a
23 °C
5 x 20: 2.5
W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15
W (1 pole)/ 2.5 W (2-pole)
per pole
Power Acceptance @ Ta > 23°C Admissible power acceptance at higher
ambient temperature see derating curves
Line Switch Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Voltage selector optional, step, 2-4 digits

Summary of content (3 pages)