Owner`s manual

25
ECO-X 36-52 / IL-X 150-200 Manual
IM100116
RD: MAY 2009
RL: 05A - BA
IS THERE VOLTAGE (24V) TO IG-
NITION CONTROL MODULE FROM
TRANSFORMER ?
CHECK ELECTRICAL CONNECTION FROM
TRANSFORMER TO IGNITION CONTROL
MODULE.
CHECK PROPER DISTRIBUTION WIRE GAUGE
ENSURE LOW VOLTAGE WIRES ARE
PROPERLY INSTALLED, WIRING POLARITY
IS CRITICAL
CHECK VA RATING ON THE TRANSFORMER.
40 VA FOR 1ST HEATER + 20 VA FOR EACH
ADDITIONAL HEATER IN THE ZONE.
YES
NO
IS THERE A SPARK AT IGNITION
SPARK IGNITER?
REFER TO SECTIONS 19 AND 20 BEFORE
PROCEEDING
ENSURE THE IGNITER GAP IS 1/4" WIDE
(6MM)
ENSURE THE FLAME SENSOR IS WITHIN
1/4” TO 1/8" ABOVE CERAMIC TILE
CHECK SPARK IGNITER CE RAMIC FOR
CRACK, REPLACE SPARK IGNITER IF NECES
SARY
CHECK HI-VOLTAGE WIRE C O N N E C T I O N
FROM SPARK IGNITER TO IGNITION MODULE
ENSURE HIGH VOLTAGE SPARKS ARE
GENERATED ON THE IGNITION CONTROL
TERMINAL BY FOLLOWING THE STEPS AS
SHOWN BELOW:
-SHUT OFF ELECTRICAL POWER
-REMOVE THE HI-VOLTAGE WIRE ON THE
IGNITION CONTROL TERMINAL
WARNING: BEFORE REMOVING HI-VOLTAGE
WIRE, ELECTRICAL POWER TO THE SYSTEM
MUST BE SHUT OFF. THIS TERMINAL CARRIES
30,000 AC VOLTS.
REFER TO SECTION 20 FOR PROCEDURE
YES
NO
CONT’D