Owner`s manual

GP-M230-BX-06A
2300 / IO 210 Manual
RD: Sept, 2005
R.L. 6
KH
5. SHUT DOWN INSTRUCTIONS
a) For temporary shutdown, turn off the electrical circuit.
b) For complete shutdown, turn off the electrical circuit and turn gas control knob to the
"OFF" position.
4. LIGHTING INSTRUCTIONS
Under certain conditions, heater may discolour due to ambient air borne particle deposits on the
surface. These deposits are normal and in no way affect the operation of the heater or the manu-
facturer's warranties. The stainless steel does not rust but will darken at flue outlet of perforated
screen over time/with extended use.
6. STAINLESS STEEL PARTS
Servicing of heater is essential for continued efficient operation. Servicing should be carried
out annually by qualified and licensed service personnel as follows:
Clean the ceramic tile with compressed air. Avoid directing air stream at gasket material
between tile and heater body. The air pressure must be lower than 20 psig.
Clean the venturi tube with compressed air. The air pressure must be lower than 20 psig.
Indication of back firing:
Loud ignition noise, followed by distinct hissing sound.
Little or no visible burning on the ceramic tile surface.
Combustion is taking place inside the burner body.
7. SERVICING GUIDE (See Heater servicing on next page)
Page 3
1. Ensure the correct voltage is supplied and gas valve is in the ON position.
2. Turn on power to heater, set thermostat (if applicable) to desired setting, the heater will light.
3. If heater does not light: Turn off power to heater, turn gas valve to OFF position.
4. Wait for five minutes and repeat steps above. If heater does not light after three attempts, call
a qualified service technician.
e) Ensure proper electrical rating in the system by checking voltage at ignition module
terminals. To avoid system malfunction, the voltage range must be within 21.6 Volts to 26.4
Volts, and correct polarity must be maintained throughout the system.
f) Test-fire the heating system by following the lighting instructions as shown below and on
heater.