Table 3: INDOOR - MINIMUM CLEARANCES TO COMBUSTIBLES
The clearance to combustible material represents the minimum distance that must be main-
tained between the outer heater surface and a nearby surface. The stated clearance to com-
bustibles represents a surface temperature of 90F° [50C°] above indoor room temperature.
It is the installers responsibility to ensure that building materials with a low heat tolerance
which may degrade at lower temperatures are protected to prevent degradation. Examples of
low heat tolerance materials include awnings, vinyl siding, fabrics, some plastics, filmy materials, etc.
Figure 3: INDOOR - MOUNTING CLEARANCES [Outdoor Clearances Page 7]
Table 4: INDOOR - SUGGESTED MOUNTING HEIGHT FOR COMFORT
MOUNTING
PARAMETERS ***
MODEL
2312 / IO 212
23,000 Btuh
MODEL
2313 / IO 213
35,000 Btuh
Mounting angle
Horizontal
MAX. 30
0
Horizontal
MAX. 30
0
Suggested height above deck/floor
9’ 0” 9’ 0” 10’ 0” 10’ 0”
NOTE: ANGLE MOUNT IS MAXIMUM 30° TO AVOID DAMAGE
Application MODEL NO
Horizontal 30° Angle Under Ends
A S T B F U E
INDOOR 2312 / IO-212 - NG/LPG 8” 10” 12.5” 2.5” 14” 60” 4”
INDOOR 2313 / IO-213 - NG/LPG 10.5” 14.5” 12.5” 2.5” 26” 60” 6”
INDOOR 2352 / IO-252 - NG Only 24” 33” 24” 24” 78” 78” 24”