INSTALLATION / OWNER’S MANUAL SERIES 1100 HIGH EFFICIENCY/COMBINED INTENSITY INFRA-RED PATIO HEATER FOR YOUR SAFETY: FIELD CONVERTIBILITY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
NOTICE: Schwank reserves the right to make changes to equipment and specifications without obligation or notification. This publication, or parts thereof, may not be reproduced in any form, without prior written consent from Schwank. Unauthorized use or distribution of this publication is strictly prohibited.
1100 SERIES HIGH EFFICIENCY/COMBINED INTENSITY INFRA-RED PATIO HEATER TABLE OF CONTENTS TOPIC PAGE NUMBER 1. GENERAL .............................................. 5 2. INSTALLATION REQUIREMENTS.... 5 2.1 MOUNTING CLEARANCES.......... 5 2.2 HEATER MOUNTING .................... 5 2.3 GAS SUPPLY LINE INSTALLATION ............................. 5 2.4 GAS PRESSURE .............................. 5 2.5 ELECTRICAL REQUIREMENTS .. 6 3. INSTALLATION PROCEDURES ........ 6 4. LIGHTING INSTRUCTIONS................
Page 4 SP-M110-CX-05B 1100 Manual R.D.: March 2006 R.L.
1. GENERAL The Schwank gas fired infra-red combined intensity heaters are suitable to be installed for heating of outdoor and indoor spaces. These installation instructions are intended for the patioSchwank Series 1100 Heaters. All installations in Canada must conform to local and national code requirements including the current CSA-B149.1-00 installation code for gas burning appliances and equipment, and Canadian Electrical Code PART 1 CSA C22.1 latest edition must be observed. All installations in the U.
A sealed regulator is supplied with the heater, which maintains the proper manifold pressure when the main burner is operating under the following pressure: NATURAL GAS PROPANE GAS LINE PRESSURE IWC MINIMUM MAXIMUM 6.0 14.0 11.0 14.0 MANIFOLD PRESSURE IWC AT TAP IN GAS VALVE 5.0 10.0 Natural gas models are orificed for 1000 BTU/CU.FT. Propane gas models are orificed for 2500 BTU/CU.FT. 2.
e) f) Ensure proper electrical rating in the system by checking voltage at ignition module terminals. To avoid system malfunction, the voltage range must be within 21.6 Volts to 26.4 Volts. Test-fire the heating system by following the lighting instructions as shown below and on heater. 4. LIGHTING INSTRUCTIONS a) b) c) d) Open the isolation valve in the main gas line, and turn gas control knob on the combination gas valve in the heater to the “ON” position. Switch on electrical circuit.
. CONFIGURATIONS: 8.1 DIMENSIONS & CONFIGURATIONS FOR THE SERIES 1100 COMBINED INTENSITY HEATERS Table 1: Capacities & Configurations MODEL 1110 1115 1120 1130 Voltage VAC 24 Current amps Capacity 40 VA Btu/hr input Radiant output 29,500 44,000 59,000 88,500 23,900 35,600 47,800 71,700 Total Weight lbs. Length < A > 49 65 74 94 21 1/4” 32 3/4” 43 1/2” 65” Diagram 1: Dimensions Front View End View 12” 8.2 OPTIONAL MOUNTING HARDWARE FOR THE SERIES 1100 COMBINED INTENSITY HEATERS.
8.3 MINIMUM CLEARANCES TO COMBUSTIBLES Table 2: MODEL 1110 1115 1120 1130 Front and rear of heater < F > Below heater 30” 30” 33” 36” 90” 96” 100” 105” Front of heater < G > < L > 66” 66” 69” 72” The clearances to combustibles are established at points reaching a surface temperature of 1600 F. Some materials such as awnings or plastic may require higher distances. Respect clearances as shown Diagram 3: horizontal mounted FRONT VIEW < 48” > <16” > < 48” > 8.
8.
8.6 WIRING DIAGRAM Page 11 SP-M110-CX-05B 1100 Manual R.D.: March 2006 R.L.
24 volt CONTROL PANEL For multiple Patio heater installations: PCP-12 PCP-4, PCP-8, PCP-12 share the same common panel 8” x 5.75” x 4” to switch up to a MAXIMUM of 12 heaters. PCP-16, PCP-24 share the same common panel 9.75” x 8” x 4” to switch up to a MAXIMUM of 24 heaters. Designed to be surface mounted INDOORS only, and preferably out of the reach of patrons. 4” 5 .7 5” 8” WARNING: MUST be used for low voltage wiring only.
8.7 PCP-12 PATIO PANEL Page 13 SP-M110-CX-05B 1100 Manual R.D.: March 2006 R.L.
9. TROUBLESHOOTING GUIDE At Patio control panel, switch heater ON Is the Heater burning ? NO The system is working properly. STOP! YES Is there 24 volts to the control panel ? YES Check voltage from the transformer, Check electrical connection at the transformer, Check line voltage to the primary side of the transformer NO Is there voltage from the control panel to the ignition control module? YES Check electrical connection from the control panel to the ignition control module.
Cont’d Is gas getting through to the burner? YES NO Ensure all gas valves are open Check orifice for obstructions (such as insects or cocoons) Check proper size orifice hole Replace orifice if necessary Is there flame failure/ flame-out after the spark generator has completed its ignition cycle. NO YES Ensure the sensing wire is securely connected to the sensing probe, Check spark igniter for cracks.
Page 16 SP-M110-CX-05B 1100 Manual R.D.: March 2006 R.L.
LIMITED WARRANTY CERTIFICATE GAS-FIRED INFRA-RED PATIO HEATER : 1100 SERIES: The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to the terms of this document.