INSTALLATION / OWNER’S MANUAL SCHWANK GAS-FIRED INFRA-RED CONSTRUCTION HEATER MODEL NUMBER: SCH-200-N / SCH-200-L CAUTION: Read all instructions before use. Retain this manual for further reference. SP-MCH2-BX-07A SCH-200 MANUAL R.
NOTICE: Schwank Inc., reserves the right to make changes to equipment and specifications without obligation or notification. All codes are current at the time of printing. This publication, or parts thereof, may not be reproduced in any form, without prior written consent from Schwank Inc. Unauthorized use or distribution of this publication is strictly prohibited. Schwank Inc. 5285 Bradco Boulevard Mississauga, Ontario, L4W 2A6 phone: (905) 712-4766 fax: (905) 712-8336 Schwank Inc.
TABLE OF CONTENTS INFORMATION AND SAFETY LABELS 4 1.0 INSTALLATION REQUIREMENTS 6 1.1 1.2 1.3 1.4 1.5 1.6 GENERAL INSTRUCTIONS GAS SUPPLY LINE/GAS PRESSURE VENTILATION REQUIREMENTS CLEARANCES TO COMBUSTIBLES MOUNTING INSTRUCTIONS LIGHTING/SHUTDOWN INSTRUCTIONS 6 6 6 6 7 8 2.0 MAINTENANCE 8 3.0 REPLACEMENT PARTS 10 4.0 LIMITED WARRANTY 12 5.
SP-MCH2-BX-07A SCH-200 MANUAL R.
For Your Information and Safety … Please read the following warning labels. WARNING WARNING Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury and property loss, damage from hazards of fire explosion, burn, asphyxiation, and carbon monoxide poisoning, Only persons who can understand and follow the instructions should use this heater. Service of this heater should be performed by a qualified service person only.
WARNING • • • • • • • • DO NOT use heater in living or office areas. Approved for heating buildings or structures under construction, alteration or repair. Use only in well ventilated areas. Heater must be used exclusively for heating purposes. The distance between the heating surface top to the nearest combustible must be at least 48 inches. The distance from the burner surface, in a horizontal plane, to the nearest combustible must be at least 52 inches.
1.0 INSTALLATION REQUIREMENTS 1.3 VENTILATION REQUIREMENTS 1.1 GENERAL INSTRUCTIONS 1. Examine contents for damage or missing parts before proceeding with these instructions. 2. Installation of heaters must conform to all local codes. 3. Ensure that heater is level before operation. 1.2 GAS SUPPLY & PRESSURE INFORMATION All piping and hose must be installed according to local code, and must be of adequate size and construction.
1.5 MOUNTING INSTRUCTIONS FIGURE 1: FREE STANDING FLOOR MOUNT A steel rod, non-combustible base is an integral part of this heater. The heater may safely be placed directly on a combustible surface. Always maintain minimum distance to combustibles as shown in Table 2. Gas supply hose/piping must lay over the top of bottom rim of heater as shown here. GAS SUPPLY LINE NOTE: Heater is equipped with a tilt safety feature. Heater will automatically shut down when it is tilted over 35 degrees.
1.6 LIGHTING / SHUTDOWN INSTRUCTIONS 1. Set thermostat to “coolest” (lowest) setting. 2. Pre-purge gas line prior to lighting. 3. Open the door in the compartment above filter section. 4. Turn gas control knob clockwise to OFF. Wait five minutes to dissipate any unburned gas. Sniff around the appliance near the floor. Don’t relight pilot if you smell gas. 5. Turn gas control knob counterclockwise to PILOT. Push down and hold the knob while you light pilot burner. 6.
Replace filter at least: FILTER RETAINER - once every 2 weeks - minimum once a day when sanding drywall - each time when connecting heater at different location * Clean burner screen with each filter change; ( see next window ) FILTER Filter replacement: - Shut off gas supply - Grasp filter retainer and pull together at retainer grips - Free filter retainer - Remove and discard filter - Replace with a new filter - Reinstall filter retainer, complete with filter Clearing Burner Screen: - Make sure gas su
3.0 REPLACEMENT PARTS TABLE 3: REPLACEMENT PARTS LIST (REFERENCE PAGE 10) ITEM NO.
FIGURE 4: REPLACEMENT PARTS DIAGRAM (REFERENCE PAGE 10) 2a 33 2b 2c 1b 1a 15 19 14 4a 16 9 20 17 8 4b 6 11 12 7 Page 8 5 SP-MCH2-BX-07A SCH-200 MANUAL R.
4.0 GAS-FIRED INFRA-RED PORTABLE HEATER LIMITED WARRANTY WHAT IS COVERED Schwank Inc. (Manufacturer) warrants that this heating product is free from defects in material or workmanship under normal use and service subject to the terms of this agreement. PROCEDURE Should you desire to assert a warranty claim, you must use the procedure described in your owner’s manual which procedure is incorporated herein by reference.
5.0 PROCEDURE FOR SERVICE OR WARRANTY CLAIM 1. Contact the dealer from whom you purchased the product or a professional gas appliance service person to determine the problem. 2. The dealer or the professional gas service person may replace or repair the defective part or require the part to be removed and shipped to the manufacturer for repair or replacement. 3.
LIMITED WARRANTY CERTIFICATE FOR GAS-FIRED INFRA-RED CONSTRUCTION HEATER : SCH SERIES The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to the terms of this document.