INSTALLATION GUIDE Isodrive 3200 4.2021 / V3.0 www.schweigen.com.
Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system. Please always retain your proof of purchase to aid in any warranty queries.
Index 1. Welcome.........................................................................................................................................2 2. Your Safety.....................................................................................................................................4 Before Installation.................................................................................................................................................................................
2. Your Safety RECEIVING YOUR RANGEHOOD Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED. If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
2. Your Safety This guide is for the installation of the Isodrive motor system after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual). NOTE: All PVC pipe and flexi ducting measurements are referring to inside measurements, unless otherwise mentioned. Motor Features • Roof and wall mounting with IPX4 degree of weather protection. • Super quiet, long vane, backward curved centrifugal fan.
2. Your Safety Minimum Mounting Height This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a floor or the ground. Avoidance of Back Flow Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire appliances. Safety of Children This fan is not intended for use by young children or infirm persons without supervision.
3. Description NOTE For more flexible ducting instructions, refer page 19. Isodrive Motor 1 2 3 4 Included in the box: 1. Isodrive 3200 motor Approx. 3 metre, 10amp cable and standard male plug 2. Fire resistant 250mm OD1 PVC riser pipe NOTE: Cable cut-out at the both ends 3. Flexible ducting (250mm) Approx. 4 metres, 250mm (260mm OD1) diameter 4. Flexible ducting (200mm) Approx. 1.5 metres, 200mm (210mm OD1) diameter 5.
4. Installation Roof Installation Recommended duct length: minimum 4 metres, optimal 4-5 metres. Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device when installing through a metal finished roof. DO NOT install on a over lapping join.
4. Installation 3200 motor Power cord 250mm PVC Pipe 50mm Pipe protrusion above dektite Dektite Fix pipe to fan module with side locking screws Fit side supports to locate Strap to supports 250mm flexible duct (minimum 4 metres ducting length fully extended) NOTE: Prevent any cord bunching by pulling cord through from plug top end 250-200mm reducer Connect to power supply 200mm flexible duct MUST keep taught Only use when connecting the motor to a single 200mm outlet on the rangehood.
4. Installation Through Wall Installation Minimum protrusion distance from wall 40mm 70mm (End of pipe) Connecting pipe Recommended to fix pipe to a support structure or strapping bracket (not included in mounting kit). Wall ø 250mm Power cable Mounting points Ensure power cable, pipe and cover plate slot is at the bottom. Wall cover plate (Optional - Part Number P2025) NOTE: Make sure that the connecting pipe is well supported, at least 2 mounting points recommended.
4. Installation 70mm Protrude pipe to distance (use as reference only) Mounting points Install fan unit last Fix pipe to structure or with a strapping bracket. Marked fastening holes first before installing Ensure slot cover plate, power cable and pipe slot is at the bottom.
4. Installation Twin 200mm Outlet Installation Example (3200 kit required) This is for use where one motor is to be used and there are two 200mm outlets. 3200 motor Ensure flexible ducting is fully extended and as short as possible. Use smooth flowing curves for maximum air flow. Remove excess ducting by trimming to length. 250 x 200 x 200mm If multi-fit Y joint supplied you will need to cut to correct size.
4. Installation Optional Back Draft Shutter Installation Through Roof • Cut 250mm flexible duct length to approximately 150mm to 200mm. • Assemble by fitting shutter assembly into the ducting. • Check to ensure the flaps close and open freely before assembling the bottom end of the ducting.
4. Installation Optional Back Draft Shutter Installation Through Wall 3200 motor PVC storm pipe Cut existing ducting length to 150mm to 200mm and assemble to the shutter system. Secure with duct tape and clamp.
4. Installation Optional Weather Shield Installation Guide Step 1 Remove Weather Shield (1 pc), P1128 Screws (2pcs) and P1128N Nuts (2pcs), Weather Shield Mounting Bracket (5 pcs) and P1124 Hex Head Screws (15pcs) from packaging. Step 2 Remove plastic cover from Weather Shield and bend to form a circle. Fasten P1128 Screws with P1128N Nuts at location shown. P1128N at the back P1128 Step 3 Place Mounting Brackets on to Fan Guard, and fasten 2 pieces of P1124 as shown.
5. Flexible Duct Flexible Ducting Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer.
5. Flexible Duct Shallow Roof Space In shallow roof spaces, do not crush or kink flexible ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 5. 90 degree curve PVC or galvanise curve 250mm flexible ducting DO NOT reduce ducting size. Figure 5 Important Note Please do not crush or kink flexible ducting, as it will reduce air flow and may cause noise to occur through the system.
5. Flexible Duct Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaffer or electrical tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2.
6. Measurements 5. Measurements Measurements for Isodrive 3200 (Not to Scale) Dimensions in mm 400 342 440 15.7 50 288 Isodrive 3200 weighs 8.3 kg without the PVC pipe. 250.
7.
7.
8. Maintenance Roof Restoration or Cleaning Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact. imporant Any damages caused by the use of chemical products are not covered by warranty. Figure 9 Avoid chemical contact to motor system. **Images for illustration purposes only. Applies for all motors.
9. Warranty / Disclaimer Warranty (See warranty for more information) Isodrive motor has a 10-Year replacement product warranty. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in this change over process. Disclaimer Under our policy of continuous product development, product specifications may change without notice.