User Manual

Page 11
Wall Installation
This type of installation is similar to roof mounting, ensuring that the pipe extends at least 50mm past the
wall surface refer gure 3. If the pipe length is shortened, reproduce the power cord exit slot on the inside of
the wall.
IMPORTANT FOR 1600 MOTOR: Weather shield must be tted to the top cover of the side ange using
the 3 screws provided. Also, it is required to use the hanging bracket for wall mount installation, for more
information please refer to page 13.
NOTE: By decreasing the length of the SteelFlex
duct from which specied (refer to installation instructions)
there will be an increase in airow and noise levels as a result. This increase in airow can cause movement of
air to be heard through the system and inhibit the system to run silently.
Figure 3: Wall installation
Wall
Wall Optional
Fitment Pipe
Weather shield
must be at top
(1600 motor only)
Optional Mounting Flange
(P40113MF*)
150mm PVC Stormwater Pipe
From outside face of ange to end of pipe
(or wall if mounting ange not used)
50
50
Locking screws to be fully
tightened engaging in holes
Locking holes at 4 and 10 o’clock
Locking screws
Power cord to
240V supply
Seal with silicone or
urethane
Fill gap between pipe
and wall or t second
wall mount ange if
required
1600
motor
*Optional wall mounting ange (P40113MF) is available
from Schweigen, please contact 1300 881 693.
4. Installation
IMPORTANT
It is a requirement to use the hanging bracket for all wall mount installations.
Please refer to the illustrations for mounting.