Installation Guide

Page 10
1.
Wall Installation
This type of installation is similar to roof mounting, ensuring that the pipe extends at least 50mm past the wall
surface refer gure 2. If the pipe length is shortened, reproduce the power cord exit slot on the inside of the
wall.
IMPORTANT FOR 1600 MOTOR: Weather shield must be tted to the top cover of the side ange using
the 3 screws provided. Also, it is required to use the hanging bracket for wall mount installation, for more
information please refer to page 15.
NOTE: By decreasing the length of the exi duct from which specied (refer to installation instructions) there
will be an increase in airow and noise levels as a result. This increase in airow can cause movement of air to
be heard through the system and inhibit the system to run silently.
Installation Without Back Draught Shutter
Figure 2 Wall Installation
Wall
Wall Optional
Fitment Pipe
Weather shield
must be at top
(1600 motor only)
Optional Mounting Flange
(P40113MF*)
150mm PVC Stormwater Pipe
From outside face of ange to end of pipe (or
wall if mounting ange not used)
50
50
Locking screws to be fully
tightened engaging in holes
Locking holes at 4 and 10 o’clock
Locking screws
Power cord to
240V supply
Seal with silicone or
urethane
Fill gap between pipe
and wall or t second
wall mount ange if
required
1600
motor
*Optional wall mounting ange (P40113MF) is available
from Schweigen, please contact 1300 829 066.
4. Installation