Installation Guide
Page 16
Figure 10 Roof mount option
Twin Motor Installation (suitable for rangehoods with one 200mm outlets)
Where two motors are to be used and there is only one 200mm outlet, follow the below methods for each
motor then join into the “Y” piece prior to joining ducting to the canopy / rangehood. Refer gure 10.
The two motors can be wired by one of the following methods:
• Wired into one plug by an electrician
• A double adaptor plugged into the lead from the canopy / rangehood
• A double GPO powered from the canopy
Cover
Try to keep length of
exible ducting as even
as possible other wise
motors will draw air o
each other
Ensure exible ducting
is fully extended and as
short as possible. Use
smooth owing curves for
maximum air ow. Remove
excess ducting by trimming
to length.
‘Y’ Junction for Twin 900/1600
Fan Installation
• 200 x 200 x 200mm
• Multi-t Y joint to be used with all
twin 1600 motor installation where
the rangehood has only one 200mm
opening
If multi-t Y joint is supplied
you will need to cut ducting to
length.
1600 motor
Z: Minimum distance
between the two fans
is 600mm.
Z
4. Installation