Owner's Manual

44
Condition/Problem Things to Check Solution
Nodisplay/partialdisplay/
unit will not turn on
Checkelectrical(wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity Allwiresincableshouldbeintact.Ifanyarevisiblycrimpedor
cut, replace cable.
Check data cable
connections/orientation
Besurecableisconnectedsecurelyandorientedproperly.Small
latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
ConsoleDisplay IfConsoleonlyhaspartialdisplayandallconnectionsarefine,
replace the Console.
Iftheabovestepsdonotresolvetheproblem,contactCustomer
Care for further assistance.
UnitoperatesbutContact
HRnotdisplayed
HRcableconnectionat
Console
BesurecableisconnectedsecurelytoConsole.
HRcableboxconnection BesurecablesfromhandlebarsandcabletoConsolearesecure
and undamaged.
Sensor grip BesurehandsarecenteredonHRsensors.Handsmustbekept
still with relatively equal pressure applied to each side.
Dryorcallousedhands Sensors may have difficulty with dried out or calloused hands.
Aconductiveelectrodecream(heartratecream)canhelpmake
better conduct. These are available on the web or at medical or
some larger fitness stores.
StaticHandlebar Iftestsrevealnootherissues,StaticHandlebarshouldbere-
placed.
UnitoperatesbutTelemet-
ricHRnotdisplayed
ChestStrap(optional) Strapshouldbe“POLAR
®
” compatible and uncoded. Make sure
strap is directly against skin and contact area is wet.
Interference Trymovingunitawayfromsourcesofinterference(TV,Micro-
wave,etc).
Replace Chest Strap IfinterferenceiseliminatedandHRdoesnotfunction,replace
strap.
Replace Console IfHRstilldoesnotfunction,replaceConsole.
UnitoperatesbutTelemet-
ricHRdisplayedincorrectly
Interference MakesurethattheHRreceiverisnotblockedbyapersonal
electronic device in the left side of the media tray.
Consoledisplays“E2”error
code
Check data cable integrity Allwiresincableshouldbeintact.Ifanyarecutorcrimped,
replace cable.
Check data cable
connections/orientation
Besurecableisconnectedsecurelyandorientedproperly.Small
latch on connector should line up and snap into place.
ConsoleElectronics Iftestsrevealnootherissues,contactCustomerCare.
TroublesHooTIng