8.3 Setting for Beep & Siren
*Door Bell (default= ON):
The Base Unit will issue a doorbell beep in Disarm Mode when receiving a triggering signal from a
Burglar sensor with its Bell in Disarm = ON.
Note: The Bell function only works for the Burglar Sensor with Bell in Disarm = Yes.
*Tamper Siren In Disarm: (default, Off)
Some of the sensors (Door Magnet, PIR, Keypad) have a Tamper sensor inside, if it was
detached from the wall or the case was opened then the sensor would issue a Tamper signal
to the Base Unit.
Tamper Siren In Disarm=On: The Siren will go off for 10 seconds, if the Base Unit receives a
Tamper signal from a sensor or controller in Disarm Mode.
*Entry Delay Beep: ON/OFF (default, ON ) (Please refer to 8.2 Entry Delay)
Entry Delay Beep ON: The Base Unit will generate beeps during the Entry Delay interval when
burglar alarm trips, the beeping speed will get faster until the end of the delay time.