User's Manual

REACTION OF LS-30 TO DIFFERENT ALARMS
The response of the LS-30 to various alarms and abnormalities is shown below. Burglar alarms can only
be issued when the system is in AWAY or HOME mode, while Fire, Panic and Medical alarms can be
triggered anytime, regardless of the system operation mode. When any of these alarms occur, the LS-30
will dial the correct phone numbers to call for help.
Burglar Alarm Response
AWAY Mode Entry Delay Burglar Alarm
System status:
(0-255 seconds)
Burglar sensor triggered Siren goes off, dialing---
If necessary, you can interrupt dialing and stop the siren by disarming the system, and clear the
alarm LED by pressing (Hot Key)
Press (Hot Key)
: stop siren, stop dialing, clear LED status.
Note 1: To pr ess the but t ons on t he Base Unit will neither send out voice nor t rigger t he sir en, in spite of
being assigned as Panic or Medical.
Sources &
Responses
Alarm
Trigger Sources Dialing Tel. Numbers
Besides CMS
Segments of voice
message
on telephone
Voice on
Base Unit
Siren Status
Burglar PIR
Door Sensor
Glass Break
Detector
Pager+ Burglar+
Common 1-4
Sequentially
Burglar+ Common Silent Programmable,
Fire Smoke Detector
Gas Detector
Pager+ Fire+
Common 1-4
Sequentially
Fire+ Common Fire Message
Programmable
Programmable,
Panic Panic button of
Remote Controller
Wireless Keypad
Pager+ Panic+
Common 1-4
Sequentially
Panic+ Common
Silent
Programmable,
Note 1
Medical Wireless Medical
Button
Pager+ Medical+
Common 1-4
Sequentially
Medical+ Common
Medical
Message
Programmable
Note 1
Programmable,
Note 1
Special Temperature Sensor
Humidity Sensor
Flood Detector
Pager+ Special+
Common 1-4
Sequentially
Special+ Common Special
Message
Programmable
Programmable
(Disarm State)
None None Silent Programmable
Sensor Tampered
Base Unit
PIR
Door Sensor
Glass Break
Detector
Wireless Keypad
(Arm State)
Same As Burglar Alarm
Sensor Trouble or
Low Battery
PIR
Door Sensor
Glass Break
Detector
Smoke Detector
Wireless Medical
Button
Special Sensor
None
None
Silent
OFF
16