User's Manual

A-5. Terminal Board Connection
_
+
+12V DC: This terminal provides +12V~15V/200mA output for the customers to connect their own
devices.
(Note: The output voltage depends on the power adaptor and will be shut down if the external
power fails.)
ALARM OUT: These two terminals are the Alarm Relay Outputs. These two terminals can be selected
as dry contacts or 9V~15V/GND output, depending on the setting of the ALARM
OUT SELECTOR.
SENSOR INPUT: There are three terminals: AUX 1 (Wire Sensor 1), AUX 2 (Wire Sensor 2) and
SENSOR IN (Wire Sensor 3), and can accept NO/NC type alarm sensor input.
Please refer to (4-4) Set Device-Wire Sensor Assignment for the settings of these
three sensor inputs.
AUX OUT 2: This output represents the status of system operation mode. In the ARM mode (AWAY
& HOME) this output will send out +5V voltage (protected by a serial 2k ohms resistor)
to this terminal. The user can connect a LED display for ARM state indication
purposes.
A-6. Connection Diagram for GSM Module
(Only available for the PCB version after LS30-02A)
GSM Antenna GSM Module
(When you receive the GSM module, you have to open the case and insert the SIM card first before operation.)
To COM1
COM1 Cable
Audio Cable
To AUX Audio
37
Wire
Sensor 1
Wire
Sensor 2
Arm LED
Indicator
Wire
Sensor 3
Wire Siren