User Manual
DataPage MK2 (USA, ECO) Desktop UHF Radio Paging System 
DPUSAECO 12    Issue 1 
4: Serial 
This connection is for units supplied with a serial port enabled and must be specified when ordering. 
It will not therefore be accessible to the user for systems supplied in the standard configuration. 
Press key 4. This sets the serial data communication speed between the transcoder and host. The screen will 
change to display: 
 BAUD RATE (1-8) 
     9600 
Enter a number in the range 1-8. 1=300, 2=600, 3=1200, 4=2400, 5=4800, 6=9600, 7= 19200, 8=38400 baud. 
After pressing ENTER, the display will change to: 
 PARITY (1-3): 
           NONE 
Enter a key in the range 1-3. 1=None, 2=Odd, 3=Even. 
After pressing ENTER, the display will change to: 
 DATA BITS (7-8): 
Enter a number in the range 7-8 to set.   >8 
4: Serial 
After pressing ENTER, the display will change to: 
 STOP BITS (1-2): 
>1 
Enter a number in the range 1-2 to set. 
After pressing ENTER, the display will change to: 
Serial Port 
Set OK. 
The default setting of the serial port is 9600, N, 8, 1 
When supplied in the standard configuration, display will read: 
Serial Port 
Not Active 