User Manual
DataPage MK2 (USA, ECO) Desktop UHF Radio Paging System 
DPUSAECO 20    Issue 1 
Appendix A 
 Example of typical Command-Acknowledge Sequence: 
CALLER  RECEIVING STATION 
<CR> every 1 second unit….. 
 ID= 
<ESC>PG1<CR> 
 <ESC>[p<CR> 
<STX>1<CR>TEST<CR><ETX>190<CR> 
(“TEST” is the message)      Processing-Please Wait<CR><ACK><CR>   
(“190” is the Checksum) 
 +++,,,,,,,,,,ATHO<CR> 
 Carrier Drop 
Example Checksum: 
The following table shows an example of a complete block containing a correct checksum which is : 
<STX>123<CR>ABC<CR><ETX>17;<CR> 
Checksum = 17
********************************************************************* 
000 * 
011 * 
011 * 
011 
000 * 
100 
100 * 
100 * 
000 * 
000 * 
 0010 * 
 0001 
 0010 * 
 0011 * 
1101 * 
 0001 * 
 0010 * 
 0011 * 
1101 * 
 0011 * 
STX * 
1 
2 
3 * 
CR * 
A * 
B * 
C * 
CR 
ETX * 
 * 
 * 
 * 
1 0111 
1 7 
 1011 
 ; * 