Service manual

OpenScape Business V1
Sales Information Page 5 04.06.2013
OpenScape Business UC Booster Card
S2
Plugin board for OpenScape Business X3R/X5/X8 if UC Suite is to be used as a UC solution
with up to 150 UC users.
OpenScape Business UC Booster Server
S2
External UC server (Linux) for OpenScape Business X3/X5/X8 if UC Suite is to be used as a
UC solution with up to 500 UC users.
SLES 11 SP2 is used on the OpenScape Business Booster Server (Linux server). OpenScape
Business Booster Server can also be run in a virtual environment with VMware vSphere.
When using the UC Booster Server, the UC Booster Card is not required. The UC Suite can
optionally also be run on all hardware models via the UC Booster Server
OpenScape Business Voice Channel Booster Card
Plugin board for the extension of OpenScape Business X3/X5/X8 with additional DSP
channels (for voice connections with IP/TDM conversion, for example).
DSP channels for up to 8 simultaneous connections are already provisioned on the
mainboard.
To increase the DSP channels, the optional OCCB/1 board is required for up to 48
simultaneous IP/TDM transitions, and beyond that, the OCCB/3 is required for up to 128 DSP
channels.
UC Software Models
S2
(Softswitch)
All-in-one server-based UC software solution that supports up to 500 IP stations with connections
to the public network using ITSP (SIP).
Independent of the platform used, OpenScape Business S
S2
can be installed on a Linux server.
SLES 11 SP2 is used as the operating system. OpenScape Business S can also be run in a
virtual environment with VMware vSphere. If TDM interfaces are required for connection to TDM
telephones or TDM trunks, OpenScape Business X3/X5/X8 can be used as a gateway.
1.2.1 Structure and Environmental Conditions
X3R X5R
X3W X5W
X8
Rack Rack Structure
Wall-mount
system
Wall-mount
system
Standard system (even for installation in rack)
89x440x380
(2U)
155x440x380
(3,5U)
Dimensions
(HxBxT in mm)
450x460x130 450x460x200
490x440x430
Weight: Rack/Wall about 6 kg
about 8 kg about 34 kg (fully loaded)
Power supply The models are equipped for connection to the power supply.
Rated input voltage (AC): 100 to 240 V
Nominal frequency: 50/60 Hz
• Battery power (DC): -48 V
Power consumption Depending on the hardware platform and expansion
Environmental
Conditions
Operating conditions: +5 to +40 °C (41 to 104 °F)
Humidity: 5 to 85%