Optional Dry Contacts 
This option must be specified at time of ordering, along with the pre-programmed messages required. 
The purchaser should also order the dry contact interface box (Part Code: DC8) for ease of 
connection to the contact terminals (see Diagram 2). 
Warning! Voltages applied to any of these contacts will cause irreparable damage! 
This unit can support up to 8 dry (volt-free) contacts on PL1, which, when shorted to ground, will send 
a pre-programmed message to a particular pager address (which could be to an individual, a group or 
all pager operatives at the same time). These messages are pre-programmed and can only be 
changed by qualified service personnel. 
The trigger time required to send a message must be greater than 1 second. 
Individual messages can be sent upon both changes of state with a maximum alphanumeric length of 
69 characters. 