User manual
41
8  FILLING
8.1   FILLING INTERSPIRO FULLY COMPOSITE CYLINDERS
The following measures must be performed when filling Divator Lite cylinders with an initial pressure 
less than 30 bar (435 psi). 
•  The filling rate must be limited to no more than 30 bar (435 psi) a minute. Using an Interspiro Fill-
ing Adapter is recommended.
•  The cylinder pack must always be filled in an upright position with the valves pointing upwards. 
•  When filling cylinders or cylinder packs having an initial pressure exceeding 30 bar (435 psi), a 
normal filling rate can be used. 
•  As a minimum, the air with which the cylinders are filled should comply with the requirements in 
European standard EN 12021 or the purity Standard for US FED SPEC BB-A-1034 Grade A.
8.2  FILLING ADAPTER
The filling adapter (item no. 99369-01) connects the cylinder valve to the filling hose.
The adapter is designed for filling Divator Lite cylinder packs 323.4 and 326.7. 
The  adapter  has  a  built-in  nozzle  that  limits  the  filling  rate  to  approximately  30  bar  (435  psi)  a 
minute. 